Consequentially, health care professionals who are purchasing examination tables and chairs typically focus on the seated height dimension....
Search Results "Evacuation Chair"
Commonly Searched Documents
-
Notes
-
Demographic Questionnaire Data
There were 37 manual WC users and 39 power wheel chair users....
-
11B-404.3 Automatic and power-assisted doors and gates
doors are difficult to open for persons using wheelchairs because holding the door open with one hand requires the user to let go of one wheel – not enough control remains to prevent the chair...
-
WHEELCHAIR
[DSA-AC] A chair mounted on wheels to be propelled by its occupant manually or with the aid of electric power, of a size and configuration conforming to the recognized standard models of...
-
Best Practice Recommendations for Layout Planning
Have event staff or volunteers in attendance at the start of each session to assist with last-minute changes (moving chairs, etc.) that may be needed....
-
Question 19
Obstacles might include boxes, shelving, or chairs....
-
Outside Surfaces
Subsets of the subjects also traveled over outdoor surfaces around the area at which they were tested with the accelerometers attached to their chairs and rated those surfaces....
-
M303 Diagnostic Equipment Used by Patients Seated in Wheelchair
used in a standing position such as mammography equipment, and also applies to equipment specifically designed for patients seated in a wheelchair such as weight scales and examination chairs...
-
3.3.10 90-Degree Turn
It also appears that there are some manual chair, power chair and scooter users who require much larger spaces than the 95th percentile values....
-
Clear Floor Space: Minimum Clear Floor Space Required - Manual, Power & Scooter
These data suggest minimum clear floor area dimensions of 786 x 1362 mm (31 x 54 in.) for manual chairs, 827 x 1414 mm (33 x 56 in.) for powered chairs, and 837 x 1435 mm (33 x 56 in.) for...
-
Safety Considerations May Necessitate an Attendant
disabled and unable to comprehend or respond appropriately to safety instructions; severely impaired with respect to mobility and would be unable to assist in the passenger’s own evacuation...
-
Egress [4.1.3(9), 4.3.10]
In multi-story buildings where stories are located above or below the level of exit discharge, evacuation elevators can be used as part of an accessible means of egress....
-
11B-215.1 General
Consult local fire departments and prepare evacuation plans taking into consideration the needs of every building occupant, including people with disabilities. ◼ ETA Editor’s Note...
-
4.21.3 Seat
When seats were used in roll-in showers, built-in shower seats were typically omitted in favor of movable shower chairs or benches to provide more room and flexibility in accommodating people...
-
5.2 Offer Suggestions
For example, you might say, “If you remove two chairs from the waiting room, it would be much easier for a wheelchair user to wait in and to get through the area.”...
-
§27.72(f)
or more carrier personnel to effect a level change the passenger needs to enter or leave the aircraft) must never be used, even if the passenger consents, unless this is the only way of evacuating...
-
F. Website
by cruise line operators; Embarkation and disembarkation policies and procedures; Accessible emergency procedures, including Muster Drills (lifeboat and emergency evacuation...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Manual Wheelchair
The accompanying table provides dimensions values for clear floor area to accommodate 95% of manual chair (n=276), power chair (n=189), and scooter (n=30) users that were measured as part...
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
The accompanying table provides dimensions values for clear floor area to accommodate 95% of scooter (n=30), power chair (n=189), and manual chair (n=276) users that were measured as part...
-
Recommendations
flat surface of 33 in. length for platforms accommodating wheeled mobility devices excluding scooters aids that can help wheelchair users mount the platform and position their chairs...
-
CONCLUSION
Access Board adopt the subcommittee's original recommendations to require an adjustable range of 19 to 25 inches for the transfer surface of examination tables and chairs during patient...
-
A4.13.9 DOOR HARDWARE
Some disabled persons must push against a door with their chair or walker to open it....
-
Maneuvering for Turns
Some power chairs also may permit tight circular turns. A three-point turn is common when using scooters and other motorized devices that have a larger turning radius....
-
Manual Wheelchairs
Alternatively, another individual can control the wheelchair using handles attached to the back of the chair....