Search Results "Elevator Lobby"
- Schumacher 1400 Series LULA Elevator - Single Opening Hoistway Plan and Section
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car...
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car...
-
407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
11B-407.3.2 Operation
Elevator hoistway and car doors shall open and close automatically....
-
Height: ADA Standard Section 407.4.6.4.1
Section 407.4.6.4.1 covers the current ADA Standards for the height of the emergency controls in elevator cars.
-
407.2.2.1 Visible and Audible Signals
Visible and audible signals shall not be required at each destination-oriented elevator where a visible and audible signal complying with 407.2.2 is provided indicating the elevator car...
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum....
- Figure 407.2.3.1 Floor Designations on Jambs of Elevator Hoistway Entrances – Drawing from the U.S. Access Board
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum. Exceptions: 1. ...
-
11B-1008.2.4.2 Elevated
The clear width of accessible routes connecting elevated play components shall be 36 inches (914 mm) minimum. Exceptions: 1....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
907.5.2.3 Visible alarms
Visible alarm notification appliances shall not be required in elevator cars....
-
407.3.4 Door and Signal Timing
equation: T = D/(1.5 ft/s) or T = D/(455 mm/s) = 5 seconds minimum where T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby...
-
11B-408.1 General
Limited-use/limited-application elevators shall comply with Section 11B-408 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....
-
11B-408.1 General
Limited-use/limited-application elevators shall comply with Section 11B-408 and with ASME A17.1. They shall be passenger elevators as classified by ASME A17.1....
-
Type: ADA Standard Section 409.4.7.1
Section 409.4.7.1: covers the current ADA Standards for the type of elevator emergency communication systems in private residence elevators.
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
1008.2.5.2 Elevated
The rise for any ramp run connecting elevated play components shall be 12 inches (305 mm) maximum....
-
407.2.1.2 Size
EXCEPTION: Existing elevator call buttons shall not be required to comply with 407.2.1.2....