The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
Search Results "Door Surface"
-
11B-407.3.3.1 Height
-
11B-407.3.3.1 Height
The device shall be activated by sensing an obstruction passing through the opening at 5 inches (127 mm) nominal and 29 inches (737 mm) nominal above the finish floor.
-
Height: ADA Standard Section 407.3.3.1
Section 407.3.3.1 covers the current ADA Standards for the height requirements of an elevators reopening device.
-
F224.1.2 Guest Room Doors and Doorways
Advisory F224.1.2 Guest Room Doors and Doorways....
-
224.1.2 Guest Room Doors and Doorways
Advisory 224.1.2 Guest Room Doors and Doorways....
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
404.2.2 Double-Leaf Doors and Gates
At least one of the active leaves of doorways with two leaves shall comply with 404.2.3 and 404.2.4.
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
Maneuvering Space at Doors
Several commenters requested that the final Guidelines incorporate minimum maneuvering clearances at doors, as provided by the ANSI Standard....
-
Surface
Surface—The top layer of ground on a recreation site, outdoor recreation access route, trail, or beach access route Firm. A surface that resists deformation by indentations....
-
Vertical Clearance: ADA Standard Section 307.4
Section 307.4 covers the current ADA Standards for vertical clearance.
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
11B-307.4 Vertical clearance
Exception: Door closers and door stops shall be permitted to be 78 inches (1981 mm) minimum above the finish floor or ground. ...
-
T208.1 General
A passenger access route shall consist of a route complying with T208.2 between wheelchair spaces and doorways, walking surfaces complying with T302, and clearances complying with T504....
-
Surface, Slope, and Openings [1011.2.2, 1011.2.3, and 1011.2.4]
The surface of the clear ground space must be firm and stable. Additional information on firm and stable surfaces is provided in the trails section of this guide....
-
4.3.6 Surface Textures
The surface of an accessible route shall comply with 4.5....
-
4.3.6 SURFACE TEXTURES
The surface of an accessible route shall comply with 4.5....
-
1132A.3 Width and height of interior doors and secondary exterior doors
Doors shall comply with the following:...
-
Acceptable Trail Surfacing Requirements
Trail surfaces are currently considered accessible only if the surfacing material is firm, stable, and slip-resistant and the trail has the engineered attributes of adequate width, moderately...
-
b. Transfer Surface Location
The MDE NPRM proposed the same location and transfer sides of the transfer surface for diagnostic equipment used by patients in the supine, prone, or side-lying position (M301) and diagnostic...
-
11B-404.2.4.3 Recessed doors and gates
, measured perpendicular to the face of the door or gate...
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....
-
404.2 Manual Doors, Doorways, and Manual Gates
Manual doors and doorways and manual gates intended for user passage shall comply with 404.2....