Section 503.5 covers the current ADA Standards for the vertical clearance at passenger loading zones.
Search Results "Door Pull"
Commonly Searched Documents
-
Vertical Clearance: ADA Standard Section 503.5
-
Door and Gate Hardware
Section 404.2.7 also covers the operating characteristics and height of door and gate hardware....
- Don-Jo Mfg., Inc. Pull Plate 7011
- Don-Jo Mfg., Inc. Pull Plate 7010
- Don-Jo Mfg., Inc. Pull Plate CFC7015
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
11B-411.3.5 Width
The width of elevator doors shall comply with Table 11B-407.4.1....
-
Doors in a Series
A few commenters expressed concern that the Guidelines did not provide design for an entrance that consists of a series of more than one door....
-
11B-404.2.8.1 Door closers and gate closers
Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum...
-
Is compliance on both sides of a door or gate required when it is usable only from one side?
No, compliance is not required on both sides of those doors or gates that can be used in one direction only. Compliance is required only on the usable side....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
-
11B-409.3 Elevator doors
Hoistway doors, car doors, and car gates shall comply with Sections 11B-409.3 and 11B-404....
- Hager Companies Push/Pull Latch 311L
-
1010.1.6 Thresholds
or landing for other doors....
-
Doors and Gates in Series [§404.2.6]
Doors and Gates in Series [§404.2.6] At hinged or pivoted doors or gates in series, a separation is required that is at least 48” plus the width of doors or gates swinging into the space...
-
4.1.3(7) Doors
(7) Doors:...
-
4.22.2 Doors
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
4.22.2 DOORS
All doors to accessible toilet rooms shall comply with 4.13. Doors shall not swing into the clear floor space required for any fixture....
-
1012.4 Surface
This section requires the surface of parking spaces and pull-up spaces to be firm and stable....
-
404 Doors, Doorways, and Gates
Changes made to the requirements for manually operated doors: clarify coverage of gates and the application of this section to manual doors and doorways intended for user passage...
-
4.13.7 Two Doors in Series
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....
-
4.13.7 TWO DOORS IN SERIES
The minimum space between two hinged or pivoted doors in series shall be 48 in (1220 mm) plus the width of any door swinging into the space....