Minimum maneuvering clearances at doors that are not automatic or power-assisted shall be as shown in Fig. 25....
Search Results "Door Control"
-
4.13.6 Maneuvering Clearances at Doors
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-604.8.1.1.2 Maneuvering space with side-opening door
In a wheelchair accessible compartment with a door located in the side wall or partition, either in-swinging or out-swinging, a minimum 60 inches (1524 mm) wide and 60 inches (1524 mm) deep...
-
11B-224.1.2 Guest room doors and doorways
11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_....
-
11B-224.1.2 Guest room doors and doorways
11B-404.2.3 _|Doors, Doorways, and Gates; Clear Width|_....
-
Usable Door
One commenter stated that a clear definition of "usable door" is required. Response....
-
11B-224.1.2 Guest room doors and doorways
Bathrooms doors shall be either sliding or hung to swing in the direction of egress from the bathroom. [2010 ADA Standards] 224.1.2 Guest Room Doors and Doorways....
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
11B-404.2.2 Double-leaf doors and gates
At least one of the active leaves of doorways with two leaves shall comply with Sections 11B-404.2.3 and 11B-404.2.4.
-
413.1.1 Caption Controls
ICT shall provide user controls for the selection of captions in at least one location that is comparable in prominence to the location of the user controls for volume....
-
Break Out Opening: ADA Standard Section 404.3.6
Section 404.3.6 covers the current ADA Standards for the break out openings at swinging or sliding doors and gates.
-
§ 38.25(c) Door height
(c) Door height....
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
11B-404.3.6 Break out opening
Where doors and gates without standby power are a part of a means of egress, the clear break out opening at swinging or sliding doors and gates shall be 32 inches (813 mm) minimum when operated...
-
407.3 Input Controls
At least one input control conforming to 407.3 shall be provided for each function....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
11B-809.10.7.5 Controls
Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum....
-
Power-Assisted Doors and Gates [§404.3]
Power-Assisted Doors and Gates [§404.3] Power-assisted devices reduce the opening force of doors with closing mechanisms....
-
1132A.1 Primary entry doors and required exit doors
1132A.1 Primary entry doors and required exit doors. The width and height of primary entry doors and all required exit doors shall comply with Section 1126A.1....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-404.2 Manual doors, doorways, and manual gates
Manual doors and doorways and manual gates intended for user passage shall comply with Section 11B-404.2....
-
11B-809.1.1 Door signal devices
In buildings with three or more residential dwelling units, the primary entry door to the dwelling unit shall be provided with a door buzzer, bell, chime or equivalent....