All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
Search Results "Covered Dwelling Unit (CBC 11A)"
-
Turning Space: ADA Standard Section 809.2.2
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
General: ADA Standard Section 229.1
Section 229.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for windows.
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
§100.205(c)(3)(iii)
(iii) Reinforcements in bathroom walls to allow later installation of grab bars around the toilet, tub, shower, stall and shower seat, where such facilities are provided; and
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
708.4.2 Residential Dwelling Unit Interface
708.4.2 Residential Dwelling Unit Interface....
-
11B-233.2 Reserved
[2010 ADA Standards] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
11B-233.2 Reserved
[2010 ADA Standards] 233.2 Residential Dwelling Units Provided by Entities Subject to HUD Section 504 Regulations....
-
F208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...