Controls shall be mounted 44 inches (1118 mm) maximum above the finish floor. The force required to activate controls shall be 5 pounds (22.2 mm) maximum.
Search Results "Closet"
-
11B-809.10.7.5 Controls
-
F213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
213.2.1 Unisex (Single-Use or Family) Toilet and Unisex Bathing Rooms
Unisex toilet rooms shall contain not more than one lavatory, and two water closets without urinals or one water closet and one urinal....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
Plan 2B: 13-Foot Wide Accessible Guest Room
shower has a 36-inch wide entry at one end of the long side of the compartment (section 608.2.3); • Recessed alternate roll-in shower location permits shorter rear grab bar at water closet...
- Willoughby Industries ETW-1490-FM-HC Floor Mount Wall Outlet Rear Mounted ADA Blow Out Type Flush Toilet
-
Single-User Toilet Rooms: Side Transfer Space
Clear floor space at water closets at least 60 inches wide allows room for side transfers. Lavatories can abut this space (or overlap it as shown on page 89)....
-
F225 Storage
[See subsections ...]
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1. Doors to...
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1. Doors...
-
225 Storage
[See subsections ...]
-
603.2.3 Door Swing
603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning...
-
225 Storage
225 Storage
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225.
-
603.2.3 Door Swing
Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space. EXCEPTIONS: 1. Doors to...
-
11B-225 Storage
[See subsections ...]
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers. Result: The entry door to the toilet...
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225.
-
11B-225 Storage
[See subsections ...]
-
11B-224.6 Storage
Fixed or built-in storage facilities within guest rooms required to provide mobility features shall comply with Section 11B-225.