Braille shall be separated 3/8 inch (9.5 mm) minimum from any other tactile characters and 3/8 inch (9.5 mm) minimum from raised borders and decorative elements....
Search Results "Character"
Commonly Searched Documents
-
Position: ADA Standard Section 703.3.2
-
1009.9 Signage
Signage shall comply with Chapter 11A, Section 1143A and Chapter 11B, Section 11B-703.5 as applicable, requirements for visual characters and include the International Symbol of Accessibility...
-
Stroke Thickness: ADA Standard Section 703.5.7
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 30 percent maximum of the height of the character....
-
Pictogram Field: ADA Standard Section 703.6.1
Characters and braille shall not be located in the pictogram field....
-
11B-703.4.2 Location
Signs containing tactile characters shall be located so that a clear floor space of 18 inches (457 mm) minimum by 18 inches (457 mm) minimum, centered on the tactile characters, is provided...
-
11B-411.4.11.3 Duration
Floor destination characters shall be displayed upon elevator car arrival at the input floor and shall not extinguish until the elevator car arrives at the destination floor....
- USDA Forest Service Built Environment Image Guide (BEIG)
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
703.4.1 Height Above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
4.30.5* Finish and Contrast
The characters and background of signs shall be eggshell, matte, or other non-glare finish....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
11B-411.2.1.4.1.2 Identification
Buttons shall be identified by raised characters and symbols, white on a black background, complying with Section 11B-703.2 and Braille complying with Section 11B-703.3....
-
4.30.3* COLOR CONTRAST
Characters and symbols shall contrast with their background - either light characters on a dark background or dark characters on a light background....
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
703.4.1 Height above Finish Floor or Ground
Tactile characters on signs shall be located 48 inches (1220 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60 inches...
-
Floor Arrival: ADA Standard Section 407.4.8.1.3
Section 407.4.8.1.3 covers the current ADA Standards for visible floor arrival indicators.
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character. ...
-
11B-703.8.9 Height above floor
Low resolution VMS characters shall be 40 inches (1016 mm) minimum above the floor of the viewing position, measured to the baseline of the character....
-
R410.2 Finish and Contrast
Characters and their background shall have a non-glare finish....
-
11B-703.8.14 Rate of change
displayed in its entirety on a single screen, it shall be displayed on a single screen and shall remain motionless on the screen for a minimum 3 seconds or one second minimum for every 7 characters...
-
11B-703.4.1 Height above finish floor or ground
mm) maximum above the finish floor or ground surface, measured from the baseline of the highest line of raised characters...
-
11B-411.2.1.2.4 Display screen
activation of the accessibility function button, the display screen shall display information including but not limited to, operating instructions, user input confirmation, elevator assignment characters...
-
Non-Tactile Signage
Non-Tactile Signage The legibility of printed characters is a function of the viewing distance, character height and proportion, font, and the color contrast between character and background...
-
T702.8 Contrast
Characters shall contrast with their background with either light characters on a dark background or dark characters on a light background....