About Commercial Thresholds Pemko manufactures thresholds in several materials to meet customer needs. Extruded Aluminum thresholds are manufactured of tempered aluminum, 6063-T6....
Search Results "Change In Direction"
Commonly Searched Documents
- PEMKO 7" Heavy Duty Threshold No. 1717
- PEMKO 9" Heavy Duty Threshold No. 1719
- PEMKO 4" Saddle Threshold No. 170
- PEMKO 5 9/16" Thermal Barrier Threshold No. 273x292-FGPK
- PEMKO 8 1/8" Thermal Barrier Threshold No. 254X4-FG
- 
    
  
  § 38.159(c)(3) Ramp threshold
  Changes in level between 1/4 inch (6.5 mm) and 1/2 inch (13 mm) shall be beveled with a slope no greater than 1:2.... 
- 
    
  
  11B-206.4.3 Entrances from tunnels or elevated walkways
  Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway... 
- 
    
  
  504.4 Tread Surface
  Changes in level are not permitted. EXCEPTION: Treads shall be permitted to have a slope not steeper than 1:48. Advisory 504.4 Tread Surface.... 
- 
    
  
  11B-206.4.3 Entrances from tunnels or elevated walkways
  Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway... 
- 
    
  
  11B-206.4.3 Entrances from tunnels or elevated walkways
  Where direct access is provided for pedestrians from a pedestrian tunnel or elevated walkway to a building or facility, all entrances to the building or facility from each tunnel or walkway... 
- 
    
  
  11B-228.1 General
  Where provided, at least one of each type of depository, vending machine, change machine, and fuel dispenser shall comply with Section 11B-309 _|Operable Parts|_.... 
- 
    
  
  5. If there is a significant risk, reasonable accommodation must be considered
  harm to health or safety, an employer still must consider whether there is a reasonable accommodation that would eliminate this risk or reduce the risk so that it is below the level of a "direct... 
- 
    
  
  21.1 Q. Is a dwelling unit that has a split entry foyer...required to be accessible if it is a ground floor unit in a covered multifamily dwelling?
  A. Yes. Under Requirement 4, there must be an accessible route into and through the dwelling unit. This would preclude a split level foyer, unless a properly sloped ramp can be... 
- 
    
  
  7.4.6 Tread Obstacles
  Tread obstacles on trails shall not exceed 2 inches (50 mm) in height measured vertically to the highest point. Where the trail surface is paved or is elevated above the natural... 
- 
    
  
  F228.1 General
  Where provided, at least one of each type of depository, vending machine, change machine, and fuel dispenser shall comply with 309. EXCEPTIONS: 1.... 
- 
    
  
  11B-228.1 General
  Where provided, at least one of each type of depository, vending machine, change machine, and fuel dispenser shall comply with Section 11B-309 _|Operable Parts|_. ... 
- 
    
  
  Signs: ADA Standard Section 216
  Section 216 covers scoping requirements in the current ADA Standards for signs. 
- 
    
  
  Signage
  Directional signage is required at inaccessible public entrances. Signage should be located to minimize backtracking.... 
- Innerface Signage Wave Interior Signage Series
- Innerface Trio Interior Signage
- Innerface Parallel Interior Signage
- Innerface Signature Interior Signage
- 
    
  
  11B-813.2.1.3 Height and operation
  Adult changing table height shall be adjustable from 17 inches (432 mm) above the floor or ground to 38 inches (965 mm) above the floor or ground, as measured to the top of the changing... 
- 
    
  
  11B-216.6 Entrances
  Directional signs complying with 703.5 that indicate the location of the nearest entrance complying with 404 shall be provided at entrances that do not comply with 404.... 
