Section 609.3 covers the current ADA Standards for the grab bar spacing between the wall, objects above, below and at the ends of the grab bar.
Search Results "CDC: Centers for Disease Control and Prevention"
-
Spacing: ADA Standard Section 609.3
-
404.3.5 Controls
404.3.5 Controls. Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
607.4.1.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
607.4.2.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the finish...
-
4.10.12(3)
Emergency controls, including the emergency alarm and emergency stop, shall be grouped at the bottom of the panel and shall have their centerlines no less than 35 in (890 mm) above the floor...
-
Delta 3-Setting 2-Port Diverter Trim - Model T11859
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Delta 3-Setting 2-Port Diverter Trim - Model T11861
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Delta 3-Setting 2-Port Diverter Trim - Model T11864
Requires the Premium User plan or above. (Login or upgrade your account!)
-
404.3.5 Controls
Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
404.3.5 Controls
Manually operated controls shall comply with 309. The clear floor space adjacent to the control shall be located beyond the arc of the door swing....
-
607.4.2.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(a)]...
-
607.4.1.2 Control End Wall
A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub. [ECTCR UFAS 4.34.5.4(3), Fig. 48(b)]...
-
11B-607.4.2.2 Control end wall
11B-607.4.2.2 Control end wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-607.4.1.2 Control end wall
11B-607.4.1.2 Control end wall. A grab bar 24 inches (610 mm) long minimum shall be installed on the control end wall at the front edge of the bathtub....
-
11B-217.4.3.2 Private buildings
Exception: In a stadium or arena, in a convention center, in a hotel with a convention center or in a covered mall, if an interior public pay telephone is provided at least one interior...
-
707.5.1 User Control
Volume control shall be provided for the speech function....
-
707.5.1 User Control
Volume control shall be provided for the speech function....
-
402.2.4 User Control
Speech output for any single function shall be automatically interrupted when a transaction is selected. Speech output shall be capable of being repeated and paused.
-
Do the exceptions for accessible routes between stories apply to facilities that are only partially occupied by entities not permitted the exception, such as health care facility or shopping center?
in private sector facilities that are either less than 3 stories or that have less than 3,000 square feet per story excluding the professional offices of health care providers, shopping centers...
-
704.3 Volume Control Telephones
704.3 Volume Control Telephones. Public telephones required to have volume controls shall be equipped with a receive volume control that provides a gain adjustable up to 20 dB minimum....
-
Sec.36.401(d)(2)(i)
(i) A shopping center or shopping mall, or a professional office of a health care provider....
-
§ 36.401(d)(2)(i)
(i) A shopping center or shopping mall, or a professional office of a health care provider....
-
Transfer Type Shower Compartments: ADA Standard Section 608.5.1
Section 608.5.1 covers the current ADA Standards for controls in transfer type shower compartments.