The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
Search Results "Adaptable Dwelling Unit (FHA)"
-
11B-809.5.3 Interconnection
-
Department of Housing and Urban Development under the Fair Housing Act
Section 809 serves to update the requirements for dwelling units contained in the current ABA requirements, the Uniform Federal Accessibility Standards (UFAS), while providing new criteria...
-
11B-233.3.1.1 Residential dwelling units with mobility features
In facilities with residential dwelling units, at least 5 percent, but no fewer than one unit, of the total number of residential dwelling units shall provide mobility features complying...
-
11B-233.3.4.1 Alterations to vacated buildings
Where a building is vacated for the purposes of alteration, and the altered building contains more than 15 residential dwelling units, at least 5 percent of the residential dwelling units...
-
11B-809.10.8.6 Controls
Faucet controls and operating mechanisms shall comply with Section 11B-309.4.
-
11B-809.10.6.4 Reinforcement for grab bars
Reinforcement for grabs bars shall comply with the following: Continuous reinforcement shall be installed in the walls of showers 30 inches (762 mm) maximum to 38 inches (965 mm)...
-
11B-809.10.8.7 Mirrors and towel bars
Where mirrors are provided the bottom edge of the reflective surface shall be 40 inches (1016 mm) maximum above the finish floor. Where towel bars are provided they shall be...
-
Overlap: ADA Standard Section 604.3.2
Section 604.3.2 covers the current ADA Standards for overlapping clearances in the water closet clear floor space.
-
F233.4.2 Residential Dwelling Units for Sale
Residential dwelling units offered for sale shall provide accessible features to the extent required by regulations issued by Federal agencies under Section 504 of the Rehabilitation Act...
-
Residential Facilities: ADA Standard Section 215.5
Section 215.5 covers scoping requirements in the current ADA Standards for fire alarm systems in residential facilities.
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-804.2.3 Turning space
In kitchens within multi-bedroom housing units and on floors containing accessible sleeping rooms with adaptable features in undergraduate student housing, turning spaces complying with...
-
11B-233.3.2 Residential dwelling units for sale
[2010 ADAS] 233.3.2 Residential Dwelling Units for Sale. ...
-
11B-809.8 Doors
Primary entry doors, required exit doors, secondary exterior doors and interior doors intended for user passage shall comply with this section and Section 11B-404.2. Doors to small...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
11B-233.3.6 Graduate student and faculty housing at a place of education
Housing facilities that are provided by or on behalf of a place of education, with residential dwelling units leased on a year round basis exclusively to graduate students or faculty, and...
-
11B-216.5.1 Parking spaces
In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required....
-
11B-216.5.1 Parking spaces
In residential facilities, where parking spaces are assigned to specific residential dwelling units, identification of accessible parking spaces shall not be required....
-
Minimum Clear Corridor Width
A few commenters from the disability community advocated a minimum clear corridor width of 48 inches. However, the majority of commenters on this issue had no objection to the...
-
§100.205(c)(2)
(2) All the doors designed to allow passage into and within all premises are sufficiently wide to allow passage by handicapped persons in wheelchairs; and
-
4.34.2(7)
(7) At least one accessible entrance to the dwelling unit shall comply with 4.14....
-
§8.32(d)
(d) For purposes of this section, section 4.1.4(11) of UFAS may not be used to waive or lower the minimum of five percent accessible units required by §8.22(b) or to apply the minimum only...
-
206.7.6 Guest Rooms and Residential Dwelling Units, F206.7.6 Guest Rooms and Residential Dwelling Units
206.7.6 Guest Rooms and Residential Dwelling Units F206.7.6 Guest Rooms and Residential Dwelling Units The final rule edits the references in these sections to the technical requirements...
-
11B-233.3.4.2 Alterations to individual residential dwelling units
of Section 11B-233.3.1 shall apply to the altered residential dwelling units until the total number of residential dwelling units complies with the minimum number required by Sections 11B...