Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17 inches (430 mm) minimum under the element....
Search Results "Water Closet Clear Floor Space"
-
306.2.3 Minimum Required Depth
-
807.2.4 Toilet and Bathing Facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
807.2.4 Toilet and Bathing Facilities
Where provided, no fewer than one water closet, one lavatory, and one bathtub or shower shall comply with the applicable requirements of 603 through 610....
-
1134A.5 Bathtubs
Floor space....
-
Feature 4 - Routes to the Meeting Space
Feature 4 - Routes to the Meeting Space Accessible interior routes to the meeting space The interior accessible route connects the accessible entrance with the meeting space....
-
Minimum Number of Accessible Parking Spaces
ADA Standards for Accessible Design 4.1.2(5) Total Number of Parking Spaces Provided (per lot) (Column A) Total Minimum Number of Accessible Parking Spaces (60" &...
-
Types of Alternative Designs
Respondents reported the following types of design alternatives: Water Closet: The water closet was moved further away from the sidewall (> 18+" from the sidewall to the centerline...
-
Ticket Prices
Venues cannot charge higher prices for accessible seats than for non-accessible seats in the same seating section. This concept also applies to service charges added to the cost of a...
-
3.5.2 Color of the ISA
Per section 703.7 of the ABAAS, the ISA shall be posted in high-contrast colors. The ISA is not required to be blue and white when posted on Federal lands.
-
Figure M5: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and 304 Diagnostic Equipment for Use by a Patient in a Standing Position (Mammography Machine Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. The mammography machine is usable by both people...
-
904.4.2 Forward Approach
Knee and toe space complying with 306 shall be provided under the counter. A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
904.4.2 Forward Approach
Knee and toe space complying with 306 shall be provided under the counter. A clear floor or ground space complying with 305 shall be positioned for a forward approach to the counter....
-
Mezzanine
An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the level or...
-
Re: Boundaries of Angled Parking Spaces
Kaylan Feel free to use as Ask A CASp question Thanks
-
Re: Boundaries of Angled Parking Spaces
Hi Roger, Would you mind if we used this question as February's "Ask A CASp" question? I'd love to get it in front of as many people as possible to see if we can get some...
-
4.1.2(9)
(9) If drinking fountains or water coolers are provided, approximately 50 percent of those provided on each floor shall comply with 4.15 and shall be on an accessible route....
-
Are the elements of path of travel and accessible routes substantively the same (such as slope, vertical clearance, width of path of travel, etc.)?
Accessible route is a fundamental term used to describe, “A continuous unobstructed path connecting accessible elements and spaces of an accessible site, building or facility that can be...
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502. ...
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502. ...
-
11B-208.2.4 Van parking spaces
For every six or fraction of six parking spaces required by Section 11B-208.2 to comply with Section 11B-502, at least one shall be a van parking space complying with Section 11B-502....
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
-
MEZZANINE
[DSA-AC] An intermediate level or levels between the floor and ceiling of any story with an aggregate floor area of not more than one-third of the area of the room or space in which the...
- ADA Sign Depot Stairwell Floor Level Sign with Tactile Text and Grade 2 Braille - 12" x 12"
-
Floor Plan of Elevator Cars [4.10.9]
Alternate dimensions that provide wheelchair turning space (60 inch diameter circle or T-turn) wholly within the car are acceptable....