Section 225.3 covers scoping requirements in the current ADA Standards for self-service storage facilities.
Search Results "Urinal Clear Floor Space"
Commonly Searched Documents
-
Self-Service Storage Facilities: ADA Standard Section 225.3
- Smith System Trespa Planner Science Table 48″ Deep
- Symmons HC3/HC4 Folding Padded Shower Seat & Grab Bar
-
11B-407.4.6.2 Buttons
Car control buttons with floor designations shall comply with Section 11B-407.4.6.2. Exception: Reserved....
-
Protruding Objects and Outdoor Recreation Access Routes
Protruding objects are defined as constructed features (such as signs) that extend into the clear width area of an outdoor recreation access route, resting interval, or passing space and...
-
11B-208.3.1 General
Exceptions: All van parking spaces shall be permitted to be grouped on one level within a multi-story parking facility....
-
R407.4 Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 915 mm (3.0 ft) minimum....
- Activar Hiawatha 535/509/536/537 Solid 1 inch Diameter Pulls
-
11B-502.6.4.1
The parking space shall be marked with an International Symbol of Accessibility complying with Section 11B-703.7.2.1 in white on a blue background a minimum 36 inches wide by 36 inches high...
-
11B-813.2.6 Shelf
No fewer than one shelf shall be provided in close proximity to the changing table at 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor....
-
11B-225.3 Self-service storage facilities
Self-service storage facilities shall provide individual self-service storage spaces complying with these requirements in accordance with Table 11B-225.3....
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
Section 36.404 Alterations: Elevator Exemption (Preamble, Section-by-Section Analysis)
As is the case with new construction, the term ‘‘shopping center or shopping mall’’ only includes floor levels housing at least one sales or rental establishment, or any floor level that...
-
Door and Gate Surfaces: ADA Standard Section 404.2.10
Section 404.2.10 covers the current ADA Standards for door and gate surfaces on manual doors and gates.
-
11B-809.10.7.3 Reinforcement for grab bars
comply with the following: Where water closets are not placed adjacent to a side wall capable of accommodating a grab bar, the bathroom shall have provisions for installation of floor-mounted...
-
11B-404.2.10 Door and gate surfaces
Swinging door and gate surfaces within 10 inches (254 mm) of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door...
-
11B-206.2.3.2 Distance to Elevators
In new construction of buildings where elevators are required by Section 11B-206.2.3, and which exceed 10,000 square feet (929 m2) on any floor, an accessible means of vertical access via...
-
11B-225.2.3 Library book stacks
Book stacks available for public use shall be 54 inches (1372 mm) maximum above the finish floor....
-
203 General Exceptions
., with racks or shelves) to be accessible. 203.9 Employee Work Areas: Spaces and elements within employee work areas shall only be required to comply with 206.2.8, 207.1, and 215.3...
-
405 Ramps
Alternate slope requirements are permitted for short ramps in existing facilities where space constraints effectively prohibit a 1:12 running slope....
-
Station 1-Physical Characteristics
Wheel spacing-measured from the center of one outside wheel to the center of the other outside wheel....
-
Leveling: ADA Standard Section 407.4.4
Section 407.4.4 covers the current ADA Standards for the self-leveling feature in elevator cars.
-
11B-407.4.4 Leveling
Each car shall be equipped with a self-leveling feature that will automatically bring and maintain the car at floor landings within a tolerance of ½ inch (12.7 mm) under rated loading to...
-
11B-809.10.6.1 Size
A water closet shall be permitted to project 12 inches (305 mm) maximum into the opening provided that 36 inches (914 mm) minimum clear space is maintained between the water closet and the...