ADA Checklist for Polling Places February 2004 Reproduction The ADA authorizes the Department of Justice to provide technical assistance to individuals and entities...
Search Results "United States Access Board"
Commonly Searched Documents
-
2004 ADA Checklist for Polling Places
-
6. MEDICAL CARE FACILITIES
[See subsections ...]
-
6.1 General
Medical care facilities included in this section are those in which people receive physical or medical treatment or care and where persons may need assistance in responding to an...
-
6.8.2 Grade and cross slope
The slope of a resting interval shall not be steeper than 1:33 (3 percent) in any direction. Where the surface is paved or is elevated above the natural ground, the surface shall not...
-
2.2 Surface
The surface of an ORAR shall be firm and stable. The type of surface should be appropriate to the setting and level of development.
-
6.1 GENERAL
In addition to the requirements of 4.1 to 4.33, Health Care buildings and facilities shall comply with 6.
-
2.5.1 Location
A resting interval shall be provided between each ORAR segment, in compliance with section 2.4.1. Depending on the design and location, the intersection of two ORARs may act as a...
-
2.4.2 Cross Slope
The cross slope of an ORAR shall be no more than 1:33 (3 percent). Where the surface is paved or is elevated above the natural ground, the cross slope shall not be steeper than 1:48...
-
Door Pressure Gauge
Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, measures forces from 0-35 pounds on one side and 0-16 kilograms on the other. If you do not...
-
Double Action Door Pressure Gauge
Double Action Door Pressure Gauge This Door Pressure Gauge, available from Evan Terry Associates, has Push-Pull capability and measures forces from 0-35 pounds on one side and...
-
Note Regarding Comparative Table
For the convenience of the reader, the Appendix to this document provides a table that lists in column one the exceptions contained in the document and in the second column, the UFAS...
-
1014.2.1.1.1 Surface
The surface of the clear ground space shall be firm and stable.
-
Raised Crossings
Raised crossings, where provided, eliminate the need for curb ramps while serving to reduce traffic speeds. Consult local Standards for application requirements, including slope...
-
Where can one get further information or technical assistance on the IBC, including its requirements for means of egress?
Technical assistance on the IBC is available from the International Code Council (ICC) at (888) ICC-SAFE (422-7233) or by email at CareCenter@iccsafe.org . For further information,...
-
Requirements for Platform Lifts
Platform Lift Clear Floor Space and Doors/ Gates
-
Garage Parking
The Standards apply to parking garages, including those provided below grade. At sites that also include surface lots, a garage is treated as a separate parking facility for...
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 _|Operable Parts|_ in the area of refuge shall activate both a light in the area of...
-
11B-604.8.1.4 Toe clearance
11B-604.8.1.4 Toe clearance. At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2.
-
1009.8.1.1 Visible communication method
[DSA-AC and HCD 1-AC] A button complying with Section 1138A.4 or Sections 11B-205 and 11B-309 in the area of refuge shall activate both a light in the area of refuge indicating that...
-
11B-604.8.1.4 Toe clearance
At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of...
-
1009.6.5 Two-way communication
Areas of refuge shall be provided with a two-way communication system complying with Sections 1009.8.1 and 1009.8.2.
-
1018.4 Clear Width
This section requires the clear width of beach access routes to be 60 inches minimum to enable individuals who use wheeled mobility devices to pass beach visitors traveling in the opposite...
-
F245.4.4 Location
Outdoor recreation access routes required by F245.4.2 and F245.4.3 shall coincide with or be located in the same area as general circulation paths. Advisory F245.4.4 Location....