[DSA-AC] A building or facility that is listed in or eligible for listing in the National Register of Historic Places, or designated as historic under an appropriate State or local law....
Search Results "Floor Designation"
Commonly Searched Documents
-
QUALIFIED HISTORIC BUILDING OR FACILITY
-
4.13.2 Revolving Doors and Turnstiles
An accessible gate or door shall be provided adjacent to the turnstile or revolving door and shall be so designed as to facilitate the same use pattern....
-
§100.205(g)(1)
units of general local government to include, in their existing procedures for the review and approval of newly constructed covered multifamily dwellings, determinations as to whether the design...
-
Stability or Stable Surface
that remains unchanged by contaminants or applied force, so that when the contaminant or force is removed, the surface returns to its original condition (2010 ADA Standards for Accessible Design...
-
4.13.2 REVOLVING DOORS AND TURNSTILES
An accessible gate or door shall be provided adjacent to the turnstile or revolving door and shall be so designed as to facilitate the same use pattern....
-
§ 35.151(a)(1)
(1) Each facility or part of a facility constructed by, on behalf of, or for the use of a public entity shall be designed and constructed in such manner that the facility or part of the...
-
11B-411.2.1.4.1.2 Identification
Identification shall be placed immediately to the left of the control button to which the designation applies....
-
§ 35.172(c)
(c) Where appropriate, the designated agency shall attempt informal resolution of any matter being investigated under this section, and, if resolution is not achieved and a violation is...
-
11B-206.7.2 Wheelchair spaces
accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 _|Assembly Areas|_ and 11B-802 _|Wheelchair Spaces, Companion Seats, and Designated...
-
§ 38.123(a)
(a) If a restroom is provided for the general public, and an accessible restroom is required by §38.111 (a) and (e) of this part, it shall be designed so as to allow a person using a wheelchair...
-
11B-411.2.1.4.1.2 Identification
Identification shall be placed immediately to the left of the control button to which the designation applies....
-
Height: ADA Standard Section 505.4
Section 505.4 covers the current ADA Standards for the height of the top of the gripping surface of handrails.
-
Classroom Acoustics: ADA Standard Section 6.
Review the updated information on the revisions to the ADA Standards regarding classroom acoustics.
-
11B-505.4 Height
A maximum height of 28 inches (710 mm) measured to the top of the gripping surface from the ramp surface or stair nosing is recommended for handrails designed for children....
-
SECTION 3101B SCOPE
Public pools include those located in or designated as the following: commercial building, hotel, motel, resort, recreational vehicle or mobile home park, campground, apartment house, condominium...
-
11B-217.4.1 Bank requirement
[2010 ADAS] EXCEPTION: TTYs shall not be required at banks of telephones located within 200 feet (61 m) of, and on the same floor as, a bank containing a public TTY. ...
-
M302.4.1 Clearance in Base
The base of the diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum...
-
M301.4.1 Clearance in Base
The base of diagnostic equipment shall provide a clearance 39 inches (990 mm) wide minimum, 6 inches (150 mm) high minimum measured from the floor, and 36 inches (915 mm) deep minimum measured...
-
3. Lavatory knee clearance
faucet hardware, the following features need to be provided -- a 29-inch-high clearance under the front edge of the lavatory, the top of the bowl mounted no higher than 34 inches above the floor...
-
707 Automatic Teller Machines and Fare Machines
Requirements address clear floor or ground space (707.2), operable parts (707.3), privacy (707.4), speech output (707.5), input (707.6), display screens (707.7), and braille instructions...
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....
-
608.7 Thresholds
maximum shall be permitted in transfer type shower compartments in existing facilities where provision of a 1/2 inch (13 mm) high threshold would disturb the structural reinforcement of the floor...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
604.9.6 Dispensers
The outlet of the dispenser shall be 14 inches (355 mm) minimum and 19 inches (485 mm) maximum above the finish floor....