size of transfer supports; • Question 23 (a) on stirrups; • Question 24 (b) on positioning supports; • Question 29 (a) on alternative dimension for minimum depth of wheelchair spaces...
Search Results "Circulation Space"
Commonly Searched Documents
-
Medical Device Manufacturers
-
MAKING THE BUILT ENVIRONMENT ACCESSIBLE
Examples include a parking space with no access aisle to allow deployment of a van’s wheelchair lift, steps at a facility’s entrance or within its serving or selling space, aisles too narrow...
-
Vanity Counter Tops
Requirements for accessible toilet and bathing rooms include a provision for vanity counter top spaces, which in the past have been omitted from accessible guest rooms even where provided...
-
Benches
Benches must have a clear floor space positioned to allow persons using wheelchairs or other mobility devices to approach parallel to the short end of a bench seat....
-
R302.7.1 Vertical Alignment
Vertical alignment shall be generally planar within pedestrian access routes (including curb ramp runs, blended transitions, turning spaces, and gutter areas within pedestrian access routes...
-
Saunas and steam rooms. (Section-by-Section Analysis)
Section 241 of the 2004 ADAAG requires newly constructed or altered saunas and steam rooms to meet accessibility requirements, including accessible turning space and an accessible bench....
-
Data Analysis
For protocols A, B and C percentages were calculated for the space needed to transfer to and from the transfer station....
-
Saunas and steam rooms. (Section-by-Section Analysis)
Section 241 of the 2004 ADAAG requires newly constructed or altered saunas and steam rooms to meet accessibility requirements, including accessible turning space and an accessible bench....
-
205.1 General
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with 309. EXCEPTIONS: 1....
-
Completing the Checklist
For example, if there is no parking provided on-site at the polling place, or only on-street parking is provided, there is no need to try to measure the size of the parking spaces or to...
-
Typical Issues
An accessible drop-off area, also known as an accessible passenger loading zone, must have a level access aisle, adjacent and parallel to the vehicle space....
-
Gurney Accessible Bathroom
Movable wall for shower gurney access Vanity remodeled to clear the space for wheelchair users Hand-held shower 6’ hose on shower Shower heads at four...
-
Exception 4
Rearranging toilet partitions to increase maneuvering space. Insulating lavatory pipes under sinks to prevent burns. Installing a raised toilet seat....
-
11B-406.5.10 Diagonal curb ramps
The bottom of diagonal curb ramps shall have a clear space 48 inches (1220 mm) minimum outside active traffic lanes of the roadway....
-
TECHNICALLY INFEASIBLE
alteration of a load-bearing member that is an essential part of the structural frame, or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
-
804.2 Clearance
EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance....
-
11B-220.1.2 Two automatic teller machines or fare machines
are provided at a location, one shall comply with Sections 11B-707.2 through 11B-707.8 and one shall comply with Sections 11B-309 _|Operable Parts|_, 11B-707.2 _|Clear Floor or Ground Space...
-
11B-208.2.3.3 Parking for guests, employees, and other non-residents
Where parking spaces are provided for persons other than residents, parking shall be provided in accordance with Table 11B-208.2....
-
F216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...
-
225.2 Storage
Where storage is provided in accessible spaces, at least one of each type shall comply with 811. Advisory 225.2 Storage....
-
219 Assistive Listening Systems
Section 219.2 requires an assistive listening system in each assembly area where audible communication is integral to the space and audio amplification is provided....
-
Bowling Lanes
Spectator seating in bowling facilities is addressed in ADAAG and will require wheelchair spaces, companion seating, and designated aisle seats. ...
-
804.2 Clearance
EXCEPTION: Spaces that do not provide a cooktop or conventional range shall not be required to comply with 804.2. Advisory 804.2 Clearance....
-
216.4.1 Exit Doors
An exit passageway is a horizontal exit component that is separated from the interior spaces of the building by fire-resistance-rated construction and that leads to the exit discharge or...