Space under an element between 230 mm (9 in) and 685 mm (2.25 ft) above the finish surface shall be considered knee clearance and shall comply with R405.3....
Search Results "Parking Space"
Commonly Searched Documents
-
R405.3.1 General
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3....
-
Occupiable
A room or enclosed space designed for human occupancy in which individuals congregate for amusement, educational or similar purposes, or in which occupants are engaged at labor, and which...
-
COMMON USE
Refers to those interior and exterior rooms, spaces, or elements that are made available for the use of a restricted group of people (for example, residents of an apartment building, the...
-
4.1.6(1)(e)
(e) If the alteration work is limited solely to the electrical, mechanical, or plumbing system and does not involve the alteration of any elements and spaces required to be accessible under...
-
306.3.1 General
Space under an element between 9 inches (230 mm) and 27 inches (685 mm) above the finish floor or ground shall be considered knee clearance and shall comply with 306.3. ...
-
Location Above Detectable Elements
Objects located above elements that are within can sweep can protrude 4” maximum from the leading edge of such elements provided that any required reach or clear floor space is not obstructed...
-
11B-202.3 Alterations
Where existing elements or spaces are altered, each altered element or space shall comply with the applicable requirements of Division 2, including Section 11B-202.4....
-
11B-203 General exceptions
Unless there is an exception, each space and/or element must be made accessible in compliance with Chapter 11B....
-
BS8300:2001 Research
They include information on space required for “kneeholes,” reaching abilities of wheeled mobility users, clear floor area space requirements and maneuvering clearances....
-
903 Benches
Commenters indicated that this provision could be misinterpreted as allowing the space to be provided in front of the bench at one end....
-
Telescopes and Periscopes
This maneuvering space must be at least 36 inches by 48 inches (915 millimeters by 1,220 millimeters)....
-
Accessible Routes
Accessible Routes Accessible routes are continuous, unobstructed paths connecting all accessible elements and spaces of a building or facility....
-
Diagonal Curb Ramps
These curb ramps must have a 48 inch minimum clear space at the bottom....
-
Visual Characters
Section 703.5 provides specifications for visual characters which address finish and contrast, case, style, character proportions and height, height, stroke thickness, and character and line spacing...
-
Using the ORAR Exceptions [F202.3, Exception 4 and 1016, Exceptions 1, 2, and 3]
Where elements or spaces in camping and picnic facilities, viewing areas, or trailheads are altered but the circulation path to the altered element or space is not changed, the circulation...
-
B. Slopes
____________________________________ ...do the interior ramps have top, middle and bottom landings that are level and at least 60" long to allow for adequate maneuvering and resting space...
-
Mounting Location and Height [4.30.6]
Space must be available for a close approach outside the swing of doors. It is important that fixed elements (e.g., drinking fountains) and furnishings not obstruct the approach....
-
3.3.13 360-Degree Turn
3.3.13 360-Degree Turn The standards on the space requirements for a 360-degree turn are quite similar across countries, ranging from 1500 mm (59 in.) in Canada and the U.K. to 1525...
-
Producing Printed Material in Large Print
magnifiers) Text should begin at the left margin (centered text is harder to read) Use right margins that are ragged, not justified (right-justified margins can create awkward spacing...
-
Where Platform Lifts are Permitted [§206.7]
In new construction, platform lifts can be used to provide an accessible route to these areas only: wheelchair spaces, performance areas, and speakers’ platforms incidental...
-
3) Signs
3) Signs ADAAG: * Signs designating permanent rooms and spaces (men's and women's rooms; room numbers; exit signs) must have raised and Brailled letters; must comply with finish and...
-
1007.6 Areas of refuge
Every required area of refuge shall be accessible from the space it serves by an accessible means of egress....
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...