When wheelchair securement systems are not in use, the systems shall not protrude into the wheelchair space except as provided in T603.5, and shall not interfere with passenger movement...
Search Results "Viewing Space"
Commonly Searched Documents
-
T604.1 General
-
14.3 Q...are there any requirements for the inside dimensions of these individual parking garages?
These garages would be public and common use space, even though the individual garages may be assigned to a particular dwelling unit....
-
B. Door Maneuvering Clearance
adequate room for a person who uses a wheelchair to approach the restroom door from the pull side and pull it open without it hitting the wheelchair - this requires at least 18" of wall space...
-
404.2.6 Doors in Series and Gates in Series
The distance between two hinged or pivoted doors in series and gates in series shall be 48 inches (1220 mm) minimum plus the width of doors or gates swinging into the space....
-
A3
Yes No Note: Unlike at an accessible parking space, the surface for the access aisle of an accessible passenger drop-off area does not have to be marked or striped....
-
C. Parking Slope
Do the parking spaces and access aisles have surface slopes less than 1:50 (i.e.: when measured as shown on the Tools & Techniques page , is the critical dimension 1/2" or less)?...
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space....
-
11B-707.9.2 Point-of-sale devices at check stands and sales or service counters
point-of-sale devices are provided at check stands and sales or service counters, they shall comply with Section 11B-707.9.1, and shall also comply with Sections 11B-707.2 _|Clear Floor or Ground Space...
-
5.1.5 Floor Height
at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear ground space...
-
Laundry Room
Adaptable closet space for an accessible washer and drier...
-
6.3(1)
EXCEPTION: Entry doors to acute care hospital bedrooms for in-patients shall be exempted from the requirement in 4.13.6 for maneuvering space at the latch side of the door if the door is...
-
5.1.5 Floor Height
at the entrance to the camp shelter is elevated above the ground surface, the floor shall be 17 (430 mm) high minimum to 19 inches (485 mm) high maximum measured from the clear ground space...
-
§ 37.123(f)(2)
(2) Additional individuals accompanying the ADA paratransit eligible individual shall be provided service, provided that space is available for them on the paratransit vehicle carrying the...
-
11B-608.1 General
Shower stalls that are 60 inches (1525 mm) wide and have no curb may increase the usability of a bathroom because the shower area provides additional maneuvering space. ◼...
-
BACKGROUND
As vacant space becomes occupied, FBE will make certain that the space is brought into full ADA compliance....
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
11B-809.4 Toilet facilities and bathing facilities
In an effort to promote space efficiency, vanity counter top space in accessible residential dwelling units is often omitted....
-
Chapter 3: Building Blocks
These requirements address floor and ground surfaces (302), changes in level (303), wheelchair turning space (304), clear floor or ground space (305), knee and toe clearance (306), protruding...
-
New Provisions for Employee Work Areas
The proposed rule required such areas to be on an accessible route so that people with disabilities could approach, enter, and exit the space....
-
6. Where multiple swings in a swing bay are provided, Section 240.2.1.1 (one of each type) requires one swing to be located on an accessible route. If an accessible route is provided to more than one swing, can each swing be counted as an accessible ground level play component? If one is an infant seat and another a sling seat, are those considered two different types?
Swing bays that provide an accessible route, clear floor or ground space, maneuvering space, and the seat at a height between 11 to 24 inches to more than one swing, can count each swing...
-
1008.2.3 Water Play Components
Where the surface of the accessible route, clear floor or ground spaces, or turning spaces serving water play components is submerged, compliance with 302, 403.3, 405.2, 405.3, and 1008.2.6...
-
208.3.2 Residential Facilities, F208.3.2 Residential Facilities
In facilities containing residential dwelling units required to provide mobility features complying with 809.2, parking spaces provided in accordance with 208.2.3.1 shall be located on the...
-
Accessible Routes
Accessible Routes Accessible routes are continuous, unobstructed paths connecting all accessible elements and spaces of a building or facility....