The height of the transfer wall shall be 16 inches (405 mm) minimum and 19 inches (485 mm) maximum measured from the deck....
Search Results "Transfer System"
-
1009.4.2 Height
-
Number of Assistive Listening Systems
number to be based on the combined seating capacity of multiple assembly areas as an alternative if two conditions are met: all receivers are usable with all provided assistive listening systems...
-
Sec. 12144. Public entity operating a demand responsive system. [Section 224]
If a public entity operates a demand responsive system, it shall be considered discrimination, for purposes of section 12132 of this title and section 794 of title 29, for such entity to...
-
Surface
Surface Since people using transfer walls are in bathing suits, their skin may be in contact with the wall....
- Sennheiser HDI 830 Two-Channel Stethoset Receiver for Wideband Transmission Systems
-
§ 37.101(e) Demand Responsive System, Vehicle Capacity of 16 or Fewer
(e) Demand Responsive System, Vehicle Capacity of 16 or Fewer....
-
§ 1194.21 Software applications and operating systems
§ 1194.21 Software applications and operating systems....
-
11B-706 Assistive listening systems
11B-706 Assistive listening systems....
-
708 Two-Way Communication Systems
708 Two-Way Communication Systems...
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
11B-1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (356 mm) minimum and 17 inches (432 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum....
-
1009.5.6 Size
Each transfer step shall have a tread clear depth of 14 inches (355 mm) minimum and 17 inches (430 mm) maximum and shall have a tread clear width of 24 inches (610 mm) minimum. ...
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
11B-1009.4.1 Clear deck space
A clear deck space of 60 inches (1524 mm) minimum by 60 inches (1524 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Clear Deck Space: ADA Standard Section 1009.4.1
A clear deck space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base of the transfer wall....
-
Transfer Surface Size: Equipment Used by Patients in a Seated Position (M302.2.2)
On diagnostic equipment used by patients in a seated position, M302.2.2 would require the size of the transfer surface to be 21 inches wide minimum and 15 inches deep minimum....
-
F - number system
The F - number system develops two number ratings, the FF and the FL....
-
230 Two-Way Communication Systems
Scoping for two-way communication systems remain unchanged in the final rule. Few comments addressed this section....
-
5.3.2.1 Transfer Sides for Stretchers
5.3.2.1 Transfer Sides for Stretchers. The transfer surface shall be located to provide the ability to transfer from a mobility device onto both long sides of the surface....
-
11B-230 Two-way communication systems
[See subsections ...]
-
11B-230 Two-way communication systems
[See subsections ...]
-
General: ADA Standard Section 230.1
Section 230.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for two-way communication systems.
-
11B-230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with Section 11B...
-
11B-230.1 General
Where a two-way communication system is provided to gain admittance to a building or facility or to restricted areas within a building or facility, the system shall comply with Section 11B...