(Significant Changes – Transfer Supports), the Access Board strengthened the transfer support requirements and added additional requirements in the final rule to ensure that supports are...
Search Results "Transfer Surface Height"
-
M305.2 Transfer Supports (Section-by-Section Analysis)
-
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302
5.4.7 Transfer Support Gripping Surface Clearance Recommendation for M301 and M302 Description: A clearance around the gripping surface is necessary to ensure sufficient space for a person...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
11B-605.2 Height and depth
Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum...
-
Carpet: ADA Standard Section 302.2
Section 302.2 covers the current ADA Standards for carpet.
-
Amusement Ride Seats Designed for Transfer
Amusement Ride Seats Designed for Transfer Where an amusement ride seat is designed for transfer,it is expected that someone will transfer only once from a wheelchair or mobility device...
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-1008.3.1.2 Height
The height of transfer platforms shall be 11 inches (279 mm) minimum and 18 inches (457 mm) maximum measured to the top of the surface from the ground or floor surface....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
11B-608.3.1 Transfer type shower compartments
In transfer type compartments, grab bars shall be provided across the control wall and back wall to a point 18 inches (457 mm) from the control wall....
-
1012.2 Height
Guards shall form a protective barrier not less than 42 inches (1067 mm) high, measured vertically above the leading edge of the tread, adjacent walking surface or adjacent seatboard....
-
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301)
5.2.1.4 Transfer Surface Size Recommendations for Imaging Equipment (M301) The Committee recommends a transfer surface size on imaging equipment be a minimum of 28 inches long by a minimum...
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
1015.3 Height
Required guards shall not be less than 42 inches (1067 mm) high, measured vertically as follows: From the adjacent walking surfaces....
-
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment
5.4.5.1 Transfer and Positioning Support Position Recommendation for Imaging Equipment On imaging equipment, the transfer surface is oriented along the long dimension of the surface where...
-
1009.5 Transfer Systems
Transfer systems shall comply with 1009.5....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
1009.4 Transfer Walls
Transfer walls shall comply with 1009.4....
-
1009.5 Transfer Systems
Transfer systems shall comply with 1009.5....
-
11B-403 Walking surfaces
[See subsections ...]
-
11B-403 Walking surfaces
[See subsections ...]
-
13.13 Permitted Transfer
13.13 “Permitted Transfer” means one of the following:...
- Smith System Husky Rectangle Activity Table 24″ Deep