§ 38.107 Restrooms
-
Sliding Doors: ADA Standard Section 408.3.1
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator sliding doors.
- Michael Graves at TEDMED 2011
-
Swinging Doors: ADA Standard Section 408.3.2
Section 408.3.1 covers the current ADA Standards for limited-use/limited-application elevator swinging doors.
-
11B-604.9.7 Toilet Compartments
Toilet compartments shall comply with Section 11B-604.8....
-
11B-604.9.7 Toilet Compartments
Toilet compartments shall comply with Section 11B-604.8....
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
11B-404 Doors, doorways, and gates
[See subsections ...]
-
404.2.4.2 Doorways without Doors or Gates, Sliding Doors, and Folding Doors
Doorways less than 36 inches (915 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 404.2.4.2....
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-404.3.5 Controls
The clear floor space adjacent to the control shall be located beyond the arc of the door swing. Advisory 11B-404.3.5 Controls. ...
-
11B-213.3.1.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one toilet...
-
11B-213.3.1.1 Toilet compartments
Where toilet compartments are provided, at least five percent of the toilet compartments, or five percent of the combination of toilet compartments and urinals, but no fewer than one toilet...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
Controls: ADA Standard Section 404.3.5
Section 404.3.5 covers the current ADA Standards for controls at automatic and power-assisted doors and gates.
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-809.10.7.1 Floor space
The floor space at water closets shall be 48 inches (1219 mm) wide minimum measured perpendicular to the side wall. A floor space 48 inches (1219 mm) wide minimum by 36 inches (914...
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
11B-404.2.4.2 Doorways without doors or gates, sliding doors, and folding doors
Doorways less than 36 inches (914 mm) wide without doors or gates, sliding doors, or folding doors shall have maneuvering clearances complying with Table 11B-404.2.4.2....
-
4.1.2(7)(d)
(d) Accessible toilet and bathing facilities when not all are accessible....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
1134A.1 General
All bathrooms, bathing and toilet facilities within covered multifamily dwelling units shall comply with this section....
-
Automatic and Power-Assisted Doors and Gates: ADA Standard Section 404.3
Section 404.3 covers the current ADA Standards for automatic and power-assisted doors and gates.
-
Closing Speed: ADA Standard Section 404.2.8
Section 404.2.8 covers the current ADA Standards for the closing speed of doors.