[See subsections ...]
Search Results "Swing Grab Bar"
Commonly Searched Documents
-
4.26 Handrails, Grab Bars, and Tub and Shower Seats
-
A4.26 Handrails, Grab Bars, and Tub and Shower Seats
[See subsections ...]
-
4.26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS
[See subsections ...]
-
A4.26 HANDRAILS, GRAB BARS, AND TUB AND SHOWER SEATS
[See subsections ...]
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
608.3.2 Standard Roll-In Type Shower Compartments
Grab bars shall not be provided above the seat. Where a seat is not provided in standard roll-in type shower compartments, grab bars shall be provided on three walls....
-
608.3.2 Standard Roll-In Type Shower Compartments
Where a seat is provided in standard roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall opposite the seat....
-
Can doors swing into turning space?
Yes, doors can swing into turning space....
-
4.26.3(2)
(2) Shear stress induced in a grab bar or seat by the application of 250 lbf (1112N) shall be less than the allowable shear stress for the material of the grab bar or seat....
-
11B-813.2.10 Door swing
Where a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space, clearance...
-
4.26.3(1)
(1) Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 lbf (1112N) shall be less than the allowable stress for the material of the grab...
-
Dispensers [4.16.6]
Dispensers [4.16.6] Toilet paper dispensers should be located below the side grab bar so that they do not obstruct use of this bar....
-
11B-803.3 Door swing
Doors shall not swing into the room unless a turning space complying with Section 11B-304.3 is provided beyond the arc of the door swing....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
11B-604.7.1 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
Showers
Comments. Several commenters requested that the final Guidelines provide dimensions on the appropriate width and height of showers and shower doors. Another commenter asked whether...
-
11B-604.7 Dispensers
The outlet of the dispenser shall be below the grab bar, 19 inches (483 mm) minimum above the finish floor and shall not be located behind grab bars....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
WET BAR
[DSA-AC] An area or space with a counter equipped with a sink and running water but without cooking facilities.
-
Turning Space: ADA Standard Section 1008.4.1
Where swings are provided, the turning space shall be located immediately adjacent to the swing....
-
608.3.3 Alternate Roll-In Type Shower Compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....
-
11B-608.3.3 Alternate roll-in type shower compartments
In alternate roll-in type shower compartments, grab bars shall be provided on the back wall and the side wall farthest from the compartment entry....