Door openings shall provide a clear width of 32 inches (815 mm) minimum....
Search Results "Smoke-Rated Door"
-
404.2.3 Clear Width
-
Are exit doors usable only in one direction required to comply on both sides?
Under the ADA Standards, compliance is not required on both sides of those doors or gates that can be used in one direction only, such as exit-only doors....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
11B-411.3 Elevator door requirements
Hoistway and car doors shall comply with Section 11B-411.3....
-
[F] 907.5.2.3.3 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.3 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
[F] 907.5.2.3.2 Groups R-1 and R-2.1
Group R-1 and R-2.1 dwelling units or sleeping units in accordance with Table 907.5.2.3.2 shall be provided with a visible alarm notification appliance, activated by both the in-room smoke...
-
4.13.11* Door Opening Force
The maximum force for pushing or pulling open a door shall be as follows:...
-
404.2.4.1 Swinging Doors and Gates
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1....
-
POWER-ASSISTED DOOR
A door used for human passage with a mechanism that helps to open the door, or relieve the opening resistance of a door, upon the activation of a switch or a continued force applied to the...
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
11B-216.4.1 Exit doors
Signs required by Chapter 10, Section 1013.4 at doors to exit passageways, exit discharge, and exit stairways shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
POWER-ASSISTED DOOR
POWER-ASSISTED DOOR....
-
404.2.1 Revolving Doors, Gates, and Turnstiles
404.2.1 Revolving Doors, Gates, and Turnstiles. Revolving doors, revolving gates, and turnstiles shall not be part of an accessible route....
-
Power-assisted Door
A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied to...
-
POWER-ASSISTED DOOR
[DSA-AC] A door used for human passage with a mechanism that helps to open the door, or relieves the opening resistance of a door, upon the activation of a switch or a continued force applied...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-407.3.4 Door and signal timing
The minimum acceptable time from notification that a car is answering a call until the doors of that car start to close shall be calculated from the following equation: T = D/(1.5 ft/...
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
11B-404.2.8.2 Spring hinges
Door and gate spring hinges shall be adjusted so that from the open position of 70 degrees, the door or gate shall move to the closed position in 1.5 seconds minimum....
-
Thresholds: ADA Standard Section 404.3.3
Section 404.3.3 covers the current ADA Standards for thresholds at automatic and power-assisted doors and gates.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.
-
11B-404.3.3 Thresholds
Thresholds and changes in level at doorways shall comply with Section 11B-404.2.5.