Furthermore, the regulations implementing Title II of the ADA specifically provide that a public entity must install curb ramps at intersections whenever it newly constructs or alters sidewalks...
Search Results "Returned Curb"
Commonly Searched Documents
-
FIRST CAUSE OF ACTION
- Texas Department of Transportation (TxDOT) Computer Aided Drawings Standard Plan Files
-
A. Background
This Chapter discusses the ADA requirements for curb ramps at pedestrian crossings that are currently enforced by the Division under PCA....
- M-D Building Products, Inc. GEN3 SmartTool™ Digital Level
-
Accessible Sidewalks 2: Pedestrians with Ambulatory Impairments
Requires the Registered User plan or above. Login!
-
25. Need for Return Trip Assistance
A passenger with a disability may need assistance for a return trip when he or she did not need that assistance on the initial trip....
-
25. Need for Return Trip Assistance
A passenger with a disability may need assistance for a return trip when he or she did not need that assistance on the initial trip....
-
4.1.6(1)(f)
(f) If an escalator or stair is planned or installed where none existed previously and major structural modifications are necessary for such installation, then a means of accessible...
-
Table 2: Summary of Department of Transportation Survey
Sidewalk cross slope 0 2% 0.47% +0.5% 5 Flatness (smoothness) of sidewalks 0 2"/10' 0.28"/10' ±1/4"/10' (±6 mm/3m) 6 Curb...
-
Typical Issues
When an accessible route crosses a curb, a curb ramp must be provided....
-
Location: ADA Standard Section 406.5
Section 406.5 covers the current ADA Standards for the location of curb ramps.
-
Handrails [§405.8, §505]
Handrails [§405.8, §505] Handrails are required on both sides of ramps with a rise greater than 6”. The Standards do not require lower handrails serving children except at ramps...
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum. EXCEPTION: Within employee work areas, the...
-
405.5 Clear Width
The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum. EXCEPTION: Within employee work areas, the...
-
11. Toilet rooms and bathing facilities
Accessible element or space ANSI A117.1 section APPLICATION 11. Toilet rooms and bathing facilities (including water closets,...
-
405.5 Clear Width
405.5 Clear Width. The clear width of a ramp run and, where handrails are provided, the clear width between handrails shall be 36 inches (915 mm) minimum. EXCEPTION: Within...
-
Exterior Routes
Changes in level greater than 1/2 inch ramped. 11B-303.4 Abrupt changes in level exceeding 4 inches, vertical dimension shall be identified by warning curb...
-
Exterior Routes
Changes in level greater than 1/2 inch ramped. 11B-303.4 Abrupt changes in level exceeding 4 inches, vertical dimension shall be identified by warning curb...
-
10. Drinking fountains and water coolers
Accessible element or space ANSI A117.1 section APPLICATION 10. Drinking fountains and water coolers 4.15 Fifty percent of...
-
1991 / 1994 ADA Standards - Plan Review Tool - Slopes
1991 / 1994 ADA Standards - Plan Review Tool - Slopes Click here to view/download the pdf "1991 / 1994 ADA Standards - Plan Review Tool - Slopes" (354 KB) * * * * * * *
-
Visual Detection of Detectable Warning Materials by Pedestrians with Visual Impairments - Final Report
(Task Order 18 under Project DTFH61-01-C-00049) Authors: James Jenness & Jeremiah Singer May 24, 2006 Prepared for: Federal Highway Administration Washington,...