T equals the total time in seconds and D equals the distance (in feet or millimeters) from the point in the lobby or corridor 60 inches (1524 mm) directly in front of the farthest call button...
Search Results "Push Button"
Commonly Searched Documents
-
11B-407.3.4 Door and signal timing
-
Location: ADA Standard Section 407.4.7.1.2
Section 407.4.7.1.2 covers the current ADA Standards for the location of designations and indicators on elevator car control buttons.
-
Why a smooth surface door or kickplate is important
This video shows what can happen if the push side of a door near the floor isn't smooth. ...
-
Re: 404.2.4.3 Recessed Doors and Gates
Notice that the text does not match the figure for a push approach door. This may be an error in the Standards, but since the text governs, it exceeds the illustrated requirement. ...
-
Controls and form elements
media player buttons, menu items, table sorting buttons form controls (e.g. ‘submit’) buttons etc....
- Doorbell Factory Medium Rectangle Stainless Steel Doorbell
-
KICK PLATE
This provides a person in a wheelchair the option of opening a door by pushing with their feet or allows the front foot plates of a wheelchair to glide smoothly along the lower face of the...
-
Keypads: ADA Standard Section 407.4.7.2
Section 407.4.7.2 covers the current ADA Standards for designations and indicators on elevator keypads.
-
11B-411.2.1.3.4 Position
Keypads or buttons shall slope away from the user at 15 to 25 degrees from the vertical plane....
-
ASME
The communication system must be push button activated. The activation button must be permanently identified with the word "HELP."...
-
11B-407.4.7.1.2 Location
Raised characters or symbols and Braille designations shall be placed immediately to the left of the control button to which the designations apply. Exception: Reserved....
- Better Living Touchless Dispenser Stainless Steel 16 oz (475 ml)
- Better Living Touchless Dispenser Stainless Steel 7.6 oz (225 ml)
- American Standard AquaWash Telescoping Bidet Seat 5900A.05G
-
11B-404.3.5 Controls
Where push plates, vertical actuation bars or other similar operating devices are provided, they shall be placed in a conspicuous location....
-
What are the auditory/braille requirements for EVCS units with a touch screen?
requirements for EVCS specifically identify that each EVCS, whether or not accessible, provided with a point-of-sale device must provide a tactilely discernable numerical keypad, like a push-button...
- American Specialties Surface Mounted Vertical Soap Dispenser 20363
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They shall be raised or flush....
-
4.10.12(1)
(1) Buttons. All control buttons shall be at least 3/4 in (19 mm) in their smallest dimension. They may be raised or flush....
- Doorbell Factory Round Stainless Steel Doorbell
- Bobrick TrimLineSeries™ Recessed Napkin/Tampon Vendor 25₵, 50₵ and Free Operation B-37063
-
11B-407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right....
-
407.4.6.2.2 Arrangement
Buttons shall be arranged with numbers in ascending order. When two or more columns of buttons are provided they shall read from left to right....