Section 407.4.6.2.2 covers the current ADA Standards for the arrangement of the elevator car control buttons.
Search Results "Private Residence Elevator"
-
Arrangement: ADA Standard Section 407.4.6.2.2
-
Buttons: ADA Standard Section 407.4.7.1
Section 407.4.7.1 covers the current ADA Standards for designations and indicators on elevator car control buttons.
-
Visible Indicators: ADA Standard Section 407.4.7.1.4
Section 407.4.7.1.4 covers the current ADA Standards for visible indicators on elevator car control buttons.
-
§ 37.3 Vehicle
Vehicle, as the term is applied to private entities, does not include a rail passenger car, railroad locomotive, railroad freight car, or railroad caboose, or other rail rolling stock described...
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
11B-411.2 Elevator landing requirements
Elevator landings shall comply with Section 11B-411.2....
-
Floor Arrival: ADA Standard Section 407.4.8.1.3
Section 407.4.8.1.3 covers the current ADA Standards for visible floor arrival indicators.
-
§ 37.29 Private entities providing taxi service
[See subsections ...]
-
Additional clarification requested
Please add 2010 ADA cite reference
-
response to feedback
Take a look now and see if there is anything else you would suggest. Thanks for the feedback.
-
402.3.1 Private Listening
Where ICT provides private listening, it shall provide a mode of operation for controlling the volume....
-
Symbols: ADA Standard Section 407.4.7.1.3
Section 407.4.7.1.3 covers the current ADA Standards for the designation and indicator symbols on elevator car control buttons.
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
11B-407.4.8.1.3 Floor arrival
As the car passes a floor and when a car stops at a floor served by the elevator, the corresponding character shall illuminate. Exception: Reserved....
-
11B-407.3.3 Reopening device
Elevator doors shall be provided with a reopening device complying with Section 11B-407.3.3 that shall stop and reopen a car door and hoistway door automatically if the door becomes obstructed...
-
Section I: Elevators
(§407.4.1) I3 Are hallway elevator call buttons 48" high or lower?...
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
11B-407.2.2.1 Visible and audible signals
In existing elevators, a signal indicating the direction of car travel shall not be required....
-
Toilet Room Configuration
The most common practice among the innovative designs was the placement of the bathroom located in a corner of a resident room with an out-swinging bathroom door oriented at 450 to the resident...
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
11B-407.4.7.2 Keypads
ETA Editor's Note The preceding CBC requirements for elevator controls at 11B-407.4.6 and 11B-407.4.7 are more stringent than those of 2010 ADA Standards....
-
11B-411.2.1.7.4 Adjacency assignment
The system shall assign an elevator car immediately to the left or right of the hall call console....