An alteration of an existing element, space, or area of a building or facility shall not impose a requirement for accessibility greater than required for new construction....
Search Results "Pedestrian Elements"
Commonly Searched Documents
-
F202.3.2 Extent of Application
-
4.34.2* MINIMUM REQUIREMENTS
An accessible dwelling unit shall have the following accessible elements and spaces as a minimum:...
-
Q14: Application of Section 504 Safe Harbor to Curb Ramps Built in Compliance with 1991 ADAAG
ramps built in compliance with 1991 ADAAG during the time period when the requirement for detectable warnings was suspended and the roadway is now being resurfaced where it intersects the pedestrian...
-
4.1.3(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
4.1.2(1)
(1) At least one accessible route complying with 4.3 shall connect accessible building or facility entrances with all accessible spaces and elements within the building or facility....
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...
-
Additional Design Specifications for Requirement 1
A few commenters stated that vehicular access was not an acceptable alternative to pedestrian access....
-
Minimum Number of Beach Access Routes [F248.2]
The number of beach access routes is not required to exceed the number of pedestrian access points provided to the beach by the entity....
-
4.1.6(1)(d)
(d) No alteration of an existing element, space, or area of a building shall impose a requirement for greater accessibility than that which would be required for new construction....
-
§27.75 Federal Highway Administration—highways.
[44 FR 31468, May 31, 1979, as amended by Amdt. 27-3, 51 FR 19017, May 23, 1986. Redesignated at 56 FR 45621, Sept. 6, 1991, as amended at 79 FR 21405, Apr. 16, 2014]
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...
-
TEST NO. 3 – UNUSUAL CHARACTERISTICS TEST
The original site characteristics result in a difference in finished grade elevation exceeding 30 inches (762 mm) and 10 percent measured between an entrance and all vehicular or pedestrian...
-
11B-213.3.2 Water closets
Where water closets are provided, at least five percent but no fewer than one shall comply with Section 11B-604. ETA Editor's Note The 2013 CBC scoping for accessible water...
-
11B-608.2.3 Alternate roll-in type shower compartments
Alternate roll-in type shower compartments shall be 36 inches (914 mm) wide and 60 inches (1524 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
Alternate Roll-in Showers
Comment. Specifications are provided for alternate roll-in showers, including their size and the location of entries (608.2.3). Comments indicated that this provision should be more...
-
608.2.3 Alternate Roll-In Type Shower Compartments
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides....
-
608.2.3 Alternate Roll-In Type Shower Compartments
608.2.3 Alternate Roll-In Type Shower Compartments. Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside...
-
4.24.2 Height
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) above the finish floor.
-
Bathrooms
Bathrooms An accessible bathroom can be equipped with either a tub or shower (transfer or roll-in).
-
4.24.4 Depth
Each sink shall be a maximum of 6‒1/2 in (165 mm) deep.
-
F212.3 Sinks
The final rule adds Exception 2 to this section, which contains the scoping requirements for sinks. Exception 2 exempts sinks in camping facilities and picnic facilities where a...
-
4.24.4 DEPTH
Each sink shall be a maximum of 6-1/2 in (165 mm) deep.
-
4.24.2 HEIGHT
Sinks shall be mounted with the counter or rim no higher than 34 in (865 mm) from the floor.