Where play components require transfer to entry points or seats, the entry points or seats shall be 11 inches (279 mm) minimum and 24 inches (610 mm) maximum from the clear floor or ground...
Search Results "Patient in Seated Position"
-
11B-1008.4.4 Entry points and seats
-
III-7.5175 Fixed seating
III−7.5175 Fixed seating (ADAAG §4.1.3(18)). At least five percent of fixed or built-in seating or tables must be accessible....
-
11B-610.3.1 Rectangular seats
The rear edge of a rectangular seat shall be 2½ inches (64 mm) maximum and the front edge 15 inches (381 mm) minimum and 16 inches (406 mm) maximum from the seat wall....
-
5.8.3.1 Breast Platform Height Recommendations
Another member emphasized the importance of considering patients of short stature in addition to considering patients seated in a wheelchair....
-
Knee & Toe Space [M303.2.4]
While discussing these issues, the subcommittee also considered positioning methods for patients using wheelchairs....
- Guldmann GLS5 Active lifter
-
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces
5.4.3.1 Positioning Support Height Recommendation for Imaging Equipment with Transfer Surfaces For imaging equipment with transfer surfaces, the Committee recommends a positioning support...
-
Seat Height [4.16.3]
Seat Height [4.16.3] Height preferences vary among people with disabilities....
- Guldmann GH1 Ceiling Lift Module
- Guldmann GH1 F Lifting Module
- Guldmann GH1 Q Lifting Module
- Guldmann GH3 Lifting Module
- Hill-Rom Likorall™ 242 S Overhead Lift
-
5.8.2.4 Unobstructed Floor Space Recommendation
While discussing these issues, the Committee also considered positioning methods for patients using wheelchairs....
-
11B-805.5 Patient Change Areas
Areas where patients change or are prepared for a procedure shall comply with Section 11B-222....
-
11B-805.5 Patient change areas
Areas where patients change or are prepared for a procedure shall comply with Section 11B-222....
-
11B-805.5 Patient change areas
Areas where patients change or are prepared for a procedure shall comply with Section 11B-222....
-
Changes in Level at Entry to Wheelchair Spaces (M303.3)
M303.3 includes technical criteria for changes in level at the entry to a wheelchair space as may occur at wheelchair weight scales with raised platforms. The technical criteria are...
-
11B-1002.4.7 Companion seats
Where the interior width of the amusement ride is greater than 53 inches (1346 mm), seating is provided for more than one rider, and the wheelchair is not required to be centered within...
-
11B-1002.4.7 Companion seats
Where the interior width of the amusement ride is greater than 53 inches (1346 mm), seating is provided for more than one rider, and the wheelchair is not required to be centered within...
-
3. Folding Seat
Do the roll-in showers have a securely fastened folding seat at 17"-19" above the floor onto which persons who use wheelchairs may transfer to shower?...
-
11B-221.1 General
Assembly areas shall provide wheelchair spaces, companion seats, designated aisle seats and semi-ambulant seats complying with Sections 11B-221 and 11B-802....
-
11B-221.1 General
Assembly areas shall provide wheelchair spaces, companion seats, designated aisle seats and semi-ambulant seats complying with Sections 11B-221 and 11B-802....
- Hussey Seating Company Roll-A-Way Seating