Openings in exterior walls in adjacent stories shall be separated vertically to protect against fire spread on the exterior of the buildings where the openings are within 5 feet (1524 mm...
Search Results "Fire Extinguisher"
Commonly Searched Documents
-
704.9 Vertical separation of openings
-
[F] 907.5.2.3 Visible alarms
In other than Group I-2 and I-2.1, visible alarm notification appliances are not required in alterations, except where an existing fire alarm system is upgraded or replaced, or a new fire...
-
4.3.11.1(4)
(4) A vestibule located immediately adjacent to an exit enclosure and constructed to the same fire-resistive standards as required for corridors and openings....
-
Destination-Oriented Elevators
programmed to stop at and automatic verbal announcement of each car stop are required Visual indicators: ½” min. character height, location above control panel/keypad or door, must extinguish...
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
-
907.2.10 Single-and multiple-station smoke alarms
Listed single-and multiple-station smoke alarms shall be installed in accordance with the provisions of this code and the household fire-warning equipment provisions of NFPA 72....
-
711.3.4 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible items beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the wall is maintained...
-
A4.3.10 EGRESS
In buildings where physically handicapped people are regularly employed or are residents, an emergency management plan for their evacuation also plays an essential role in fire safety....
-
709.4 Continuity
The supporting construction shall be protected to afford the required fire-resistance rating of the wall or floor supported in buildings of other than Type IIB, IIIB or VB construction....
-
711.4.3 Nonfire-resistance-rated assemblies
Penetrations of horizontal assemblies without a required fire-resistance rating shall meet the requirements of Section 707 or shall comply with Sections 711.4.3.1 through 711.4.3.2....
-
711.4.5 Dissimilar materials
Noncombustible penetrating items shall not connect to combustible materials beyond the point of firestopping unless it can be demonstrated that the fire-resistance integrity of the horizontal...
-
809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation....
- FindLaw - ADA: Disabilities & Your Rights as an Employee
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection and building fire alarm activation, and carbon monoxide detection...
-
11B-809.5.3 Interconnection
The same visible alarm appliances shall be permitted to provide notification of residential dwelling unit smoke detection, building fire alarm activation, and carbon monoxide detection....
-
[F] 907.5.2.3.1 Public and common use areas
and shower rooms Music practice rooms Band rooms Multipurpose rooms Occupational shops Occupied rooms where ambient noise impairs hearing of the fire...
-
704.6 Structural stability
shall extend to the height required by Section 704.11 and shall have sufficient structural stability such that it will remain in place for the duration of time indicated by the required fire-resistance...
-
4.3.11.1(5)
(5) A portion of a stairway landing within an exit enclosure which is vented to the exterior and is separated from the interior of the building with not less than one-hour fire-resistive...
-
11B-504.8 Floor identification
Identification Signs" referenced in CBC 11B-504.8 and in the second paragraph (only) of 1023.9 should not be confused with the "Stairway Identification Signs" (hereinafter termed the "Fire...
-
Emergency Communication [§407.4.9]
The visual indication must be on the same panel as the “HELP” push button and extinguish when a communications link is terminated....
-
Attachment J
Within 1 year, the City of Waukegan will make the following modifications to the Waukegan Fire Station #1: None of the 27 parking spaces available to the public have vertical...
-
704.11.1 Parapet construction
Parapets shall have the same fire-resistance rating as that required for the supporting wall, and on any side adjacent to a roof surface, shall have noncombustible faces for the uppermost...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...