Covered multifamily dwellings in buildings without an elevator, located on sites with difficult terrain conditions or unusual characteristics, may employ the site impracticality tests in...
Search Results "Construction Site"
Commonly Searched Documents
-
1150A.1 General
-
1150A.1 General
Covered multifamily dwellings in buildings without an elevator, located on sites with difficult terrain conditions or unusual characteristics, may employ the site impracticality tests in...
-
6.11 Protruding Objects
Constructed features, including signs, shall not extend into the space above a beach access route more than 4 inches (100 mm) if they are between 27 inches (685 mm) and 80 inches (2030...
-
Revised and New Standards for Buildings and Facilities
The 2010 ADA Standards for Accessible Design include revised and new minimum requirements for newly and constructed or altered facilities so that they are accessible to and usable by individuals...
-
VII. New Construction and Alterations
Public entities must ensure that newly constructed buildings and facilities are free of architectural and communication barriers that restrict access or use by individuals with disabilities...
-
Section 35.151(d) Scope of Coverage (Section-by-Section Analysis)
Once the construction or alteration of a facility has been completed, all other aspects of programs, services, and activities conducted in that facility are subject to the operational requirements...
-
4.8.2* Slope and Rise
The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
4.8.2* SLOPE AND RISE
The maximum slope of a ramp in new construction shall be 1:12. The maximum rise for any run shall be 30 in (760 mm) (see Fig. 16)....
-
Camping and Picnic Facilities [F244.2.3.1, F244.3, F245.2.5.1, and F244.5.3]
Within camping and picnic units with mobility features (figure 16), at least one of each type of outdoor constructed feature must comply with the applicable technical requirements for the...
-
Section 35.151(d) Scope of coverage (Section-by-Section Analysis)
Once the construction or alteration of a facility has been completed, all other aspects of programs, services, and activities conducted in that facility are subject to the operational requirements...
-
Outdoor Constructed Feature
A constructed element provided at an outdoor recreation site such as a picnic table; fire ring; pedestal grill; tent pad; bench; trash, recycling, or other essential container; fireplace...
-
11B-233.3.1.2.6.5 Additional requirements.
1. Grab bar reinforcement complying with Sections 11B-809.10.5.2, 11B-809.10.6.4, or 11B-809.10.7.3. 2. Interior door opening width complying with Section 11B-404.3.1. 3....
-
Standards Applicable Under Section 504 as of March 15, 2012
In addition, effective March 15, 2012, because the 1991 Standards will no longer be an applicable standard under the ADA for any new construction and alterations, we are announcing that...
- Kompan, Inc. M243 - Crocodile Bench
-
Sec.36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...
-
§ 35.151(c) Accessibility standards
(c) Accessibility standards.
-
Requirements to Remember for: Light Rail Projects
[See subsections ...]
-
Public entrances
Sixty percent of all public entrances to the facility must be accessible. If there are only two entrances, both must be accessible. (DOT ADA Standard 206.4.1.)
-
ADA & Level Boarding - Perfromance [sic] Standards on Station-by-Station Basis
49 CFR §37.42(d)(2) DECEMBER 14, 2011
-
§ 36.401(a)(2)(i)
(i) If the last application for a building permit or permit extension for the facility is certified to be complete, by a State, County, or local government after January 26, 1992...
-
1011.2.4 Openings
This section requires openings in the clear ground space such as drainage grates to not allow passage of a sphere more than 1/2 inch in diameter. Where possible, drainage grates...
-
1011.2.4 Openings
Openings in the clear ground space surface shall not allow the passage of a sphere more than 1/2 inch (13 mm) in diameter. Advisory 1011.2.4 Openings. Where possible, drainage...