and operable parts for ICT functions are located in maintenance or monitoring spaces but they are operated remotely, the remote controls or interfaces would also not be permitted this exception...
Search Results "General Exception"
Commonly Searched Documents
-
E202.4 ICT Functions Located in Maintenance or Monitoring Spaces
-
10.2.1(3)
EXCEPTION: Bus schedules, timetables, or maps that are posted at the bus stop or bus bay are not required to comply with this provision....
-
4.13.5 Clear Width
EXCEPTION: Doors not requiring full user passage, such as shallow closets, may have the clear opening reduced to 20 in (510 mm) minimum....
-
Chapter 10: Recreation Facilities
The final rule also adds the conditions for using the exceptions to the specific provisions in these technical requirements at 1019....
-
5.3.6 Entrance
Exception: Where bedrock, perma-frost or other environmental conditions prohibit a level entry or the toilet design (such as a composting toilet) necessitates a raised toilet structure,...
-
4.1.6(1)(b)
installed where none existed previously, then a means of accessible vertical access shall be provided that complies with 4.7, Curb Ramps; 4.8, Ramps; 4.10, Elevators; or 4.11, Platform Lifts; except...
-
F247.4.4 Routes
An exception to F213.1 exempts pit toilets from the requirements for accessible toilet facilities....
-
4.22.3 CLEAR FLOOR SPACE
EXCEPTION: In toilet rooms with only one water closet and one lavatory, a clear floor space of 30 in by 60 in (815 mm by 1525 mm) may be used in lieu of the unobstructed turning space....
-
4.1.1(6)
EXCEPTION: These provisions are not mandatory for single user portable toilet or bathing units clustered at a single location; however, at least one toilet unit complying with 4.22 or one...
-
11B-411.2.1.1 Location
Exception: Hall call consoles beyond those required by Section 11B-411.2.1.1 shall be permitted to be provided outside the elevator landing and to be wall-mounted, pedestal-mounted, or mounted...
-
§ 35.151(e)(2)
Transfer-type showers are not permitted in lieu of a roll-in shower with a seat, and the exceptions in sections 608.3 and 608.4 for residential dwelling units are not permitted....
-
§ 37.43(c)
include, but are not necessarily limited to, ticket purchase and collection areas, passenger waiting areas, train or bus platforms, baggage checking and return areas and employment areas (except...
-
§ 35.151(g)(3)
(3) Wheelchair spaces and companion seats are not located on (or obstructed by) temporary platforms or other movable structures, except that when an entire seating section is placed on temporary...
-
11B-1009.3.2 Submerged depth
Exception: In wading pools, the sloped entry and landings, if provided, shall extend to the deepest part of the wading pool....
-
11B-403.5.2 Clear width at turn
Exception: Where the clear width at the turn is 60 inches (1524 mm) minimum compliance with Section 11B-403.5.2 shall not be required....
-
11B-206.4.4.2 Direct connections
Exception: In key stations and existing intercity rail stations, existing direct connections shall not be required to comply with Section 11B-404....
-
11B-206.4.5 Tenant spaces
Exception: Self-service storage facilities not required to comply with Section 11B-225.3 shall not be required to be on an accessible route. ...
-
11B-804.2 Clearance
Exception: Spaces that do not provide a cooktop or conventional range shall not be required to comply with Section 11B-804.2. [2010 ADAS] Advisory 804.2 Clearance....
-
11B-233.3.1.2 Residential dwelling units with adaptable features
Exception: The number of required adaptable residential dwelling units shall be reduced by the number of units required by Section 11B-233.3.1.1. ...
-
11B-231.4.1 Cubicles and counters
Exception: The detainee side of cubicles or counters at non-contact visiting areas not serving holding cells required to comply with Section 11B-231 shall not be required to comply with...
-
11B-403.5.2 Clear width at turn
Exception: Where the clear width at the turn is 60 inches (1524 mm) minimum compliance with Section 11B-403.5.2 shall not be required....
-
11B-407.4.6.1 Location
Exceptions: Where the elevator panel serves more than 16 openings and a parallel approach is provided, buttons with floor designations shall be permitted to be 54 inches (1372 mm)...
-
11B-602.2 Clear floor space
Exception: A parallel approach complying with Section 11B-305 shall be permitted at units for children's use where the spout is 30 inches (762 mm) maximum above the finish floor or ground...
-
11B-216.8.1 Geometric symbols
Exceptions: Geometric symbols shall not be required at entrances to toilet and bathing rooms located within private or semi-private rooms or spaces....