At least one side partition shall provide a toe clearance of 9 inches (229 mm) minimum above the finish floor and 6 inches (152 mm) deep minimum beyond the compartment-side face of the partition...
Search Results "Floor-Level Exit Sign"
Commonly Searched Documents
-
11B-604.8.1.4 Toe clearance
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
3. FIXTURES and HARDWARE
When provided, a fold-down shelf shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor.”xx Shelves: “If the clear floor space allows a parallel...
-
11B-608.5.2 Standard roll-in type shower compartments
seat wall 19 inches (483 mm) minimum and 27 inches (686 mm) maximum from the seat wall; and shall be located above the grab bar, but no higher than 48 inches (1219 mm) above the shower floor...
-
11B-809.12 Electrical receptacles, controls and switches
When the reach is over a kitchen work surface and base cabinet, the work surface shall be 36 inches (914 mm) maximum above the finish floor and 25 1/2 inches (650 mm) maximum in depth....
- Dyson Airblade dB Hand Dryer
-
Spy City Café
bottom edges of the reflecting surfaces of the mirrors in the men's and women's toilet rooms located outside the Café and designated as accessible are mounted 57 ½" [sic] from the finished floor...
-
604.8.1.4 Toe Clearance
The front partition and at least one side partition shall provide a toe clearance of 9 inches (230 mm) minimum above the finish floor and 6 inches (150 mm) deep minimum beyond the compartment-side...
-
604.7 Dispensers
The outlet of the dispenser shall be 15 inches (380 mm) minimum and 48 inches (1220 mm) maximum above the finish floor and shall not be located behind grab bars....
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
1002.4.4.3 Permitted Protrusions in Wheelchair Spaces
permitted to protrude a distance of 6 inches (150 mm) maximum along the front of the wheelchair space, where located 9 inches (230 mm) minimum and 27 inches (685 mm) maximum above the floor...
-
307.4 Vertical Clearance
The leading edge of such guardrail or barrier shall be located 27 inches (685 mm) maximum above the finish floor or ground....
-
Extensions
Extensions must be rounded or returned to the walls, floors, or posts....
-
4.8.1 General
One fixed showerhead shall be 48 inches (1220 mm) above the floor or ground surface, and one fixed shower head shall be 72 inches (1830 mm) minimum above the floor or ground surface....
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-407.2.1.4 Location
A destination-oriented elevator system provides lobby controls enabling passengers to select floor stops, lobby indicators designating which elevator to use, and a car indicator designating...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum above the floor...
-
11B-216.5.1 Parking spaces
Parking spaces complying with Section 11B-502 shall be identified by signs complying with Section 11B-502.6. Exceptions: 1. Reserved. [2010 ADAS] 1. ...
-
R309.1 General
Accessible parking spaces must be identified by signs displaying the International Symbol of Accessibility (see R211.3 and R411)....
-
Start Outside
If there is an accessible entrance, determine if there are signs at inaccessible entrances directing people to the accessible entrance. Go inside and continue through the facility....
-
Protruding Object
A constructed feature such as a sign that extends into the trail tread more than 4 inches (100 mm) between 27 inches (685 mm) and 80 inches (2030 mm) above the trail tread. ...
-
Pictograms
Pictorial symbols used for other types of signs (e.g., no smoking, occupant logos) are not addressed by ADAAG....
-
Americans with Disabilities Compliance Clause for the Group
., alternate format materials or sign language interpreters) for the Group’s functions, and modification of the Group’s policies, practices and procedures to ensure that attendees with disabilities...