Spaces between the boards in a boardwalk and drainage grates are examples of openings. ...
Search Results "Clear Ground Space"
-
1016.6 Openings
-
604.8.1.6 Lavatory
The lavatory shall be mounted so as not to overlap the clear floor space areas required by section 604 for the wheelchair accessible toilet compartment and shall comply with section 606....
-
Controls
Clear floor space at controls should be located outside the door swing....
-
Controls [9.2.2(5)]
Controls [9.2.2(5)] All controls in accessible units, sleeping rooms, and suites must comply with 4.27, which provides specifications for clear floor space, height of operable controls...
-
1016.6 Openings
Spaces between the boards in a boardwalk and drainage grates are examples of openings....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
11B-411.2.2.1 Visible identification
The identification fixture shall be 80 inches (2032 mm) minimum above the finish floor or ground to the bottom of the fixture....
-
Maneuvering Clearances at Doors [4.13.6]
Maneuvering Clearances at Doors [4.13.6] Pull-side clearance beyond the door swing provides space for a forward reach to door hardware....
-
ABA CHAPTER 8: SPECIAL ROOMS, SPACES, AND ELEMENTS
[See subsections ...]
-
4. ACCESSIBLE ELEMENTS AND SPACES: SCOPE AND TECHNICAL REQUIREMENTS
[See subsections ...]
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
1132A.5.2 Strike edge maneuvering space at doors
The width of the level area on the side to which the door swings shall extend 18 inches (457 mm) past the strike edge for all doors. The width of the level area at the exterior side...
-
Display Screens
floor space in front of the automated kiosk....
-
Coat Hooks and Shelves: ADA Standard Section 803.5
Shelves shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor or ground....
-
Error/Omission: When a transfer shower is used, it is often larger than the required 36" x 36" size.
Except as specified in 9.1.2, shower stall size and clear floor space shall comply with Fig. 35(a) or (b). The shower stall in Fig. 35(a) shall be 36 in by 36 in (915 mm by 915 mm)....
-
Talking Three-Dimensional Models for Way-finding
People generally find it easier to draw a spatial analogy between the physical world and a scale model than to comprehend a raised-line map of the same space....
-
11B-240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
11B-240.1 General
In existing play areas, where play components are relocated for the purposes of creating safe use zones and the ground surface is not altered or extended for more than one use zone, the...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
11B-405.7.4 Change in direction
Ramps that change direction between runs at landings shall have a clear landing 60 inches (1525 mm) minimum by 72 inches (1829 mm) minimum in the direction of downward travel from the upper...
-
Handrails: ADA Standard Section 1008.2.5.3
Handrails shall not be required on ramps located within ground level use zones. 2. Handrail extensions shall not be required....
-
Clearance Reduction: ADA Standard Section 306.3.4
Section 306.3.4 covers the current ADA Standards for knee clearance width reduction.
-
11B-203.11 Water slides
An accessible route complying with Division 4 shall be provided to the ground- or floor-level entry points, where provided, of stairs, ladders, or other means of reaching the raised elements...