Where space beneath an element is included as part of clear floor or ground space or turning space, the space shall comply with Section 11B-306....
Search Results "Section 505"
-
11B-306.1 General
-
11B-405.7 Landings
Landings shall comply with Section 11B-405.7. Advisory 11B-405.7 Landings....
-
HOUSING AT A PLACE OF EDUCATION
The applicability of CBC Chapter 11B for housing at a private school, college, or university is addressed in Section 11B-224.7 and 11B-224.7.1....
-
11B-802.1.2 Width
It should be noted that although side access to the wheelchair space is allowed, companion seating in compliance with Section 11B-802.3 must also be provided adjacent to each wheelchair...
-
11B-209.5 Mechanical access parking garages
Mechanical access parking garages shall provide at least one passenger drop-off and loading zone complying with Section 11B-503 at vehicle drop-off and vehicle pick-up areas....
-
11B-410.6 Doors and gates
Platform lifts shall have low-energy power-operated doors or gates complying with Section 11B-404.3. Doors shall remain open for 20 seconds minimum....
-
11B-1008.4.3 Play tables
Exception: Play tables designed and constructed primarily for children 5 years and younger shall not be required to provide knee clearance where the clear floor or ground space required by Section...
-
1.1.3 Scope
In alteration projects, these provisions apply to the area of new work, and include the path of travel requirements found in Section 11B-202.4. ◼...
-
11B-223.3 Long-term care facilities
care facilities and nursing homes, at least 50 percent, but no fewer than one, of each type of patient bedroom or resident sleeping room shall provide mobility features complying with Section...
-
11B-602.9 Pedestrian protection
The protected area within which a drinking fountain is located shall be 32 inches (813 mm) wide minimum and 18 inches (457 mm) deep minimum, and shall comply with Section 11B-305.7....
-
1.9.1.1.4
permit, building standards published in the California Building Standards Code relating to access for persons with disabilities and other regulations adopted pursuant to Government Code Section...
-
1.9.1.4.1
California Government Code Section 4453(a) vests enforcement authority to the Director of the Department of General Services (generally delegated to the Division of the State Architect)...
-
Accessible Routes in Dwelling Units with Mobility Features
Sections 4.34.1 and 4.34.2 of the UFAS require the living area, kitchen and dining area, bedroom, bathroom, and laundry area, where provided, in covered dwelling units with mobility features...
-
11B-809.5.2 Residential dwelling unit smoke detection system and carbon monoxide detection system
Residential dwelling unit smoke detection systems shall comply with Chapter 9, Section 907.2.11....
-
Two Drinking Fountains
Many comments considered this section unduly complicated and obscure in potentially requiring at least two units where drinking fountains are provided....
-
Physical or mental impairments
Section 504 defines a physical or mental impairment as any physiological disorder or condition, cosmetic disfigurement, or anatomical loss affecting one or more...
-
Substantial limitation
The determination of substantial limitation must be made on a case-by-case basis with respect to each individual student.21 Section 504 requires that, for elementary and secondary school...
-
7(2) Usable bathrooms
To meet the requirements of section 100.205(c)(3)(iv) either: All bathrooms in the dwelling unit comply with the provisions of paragraph (a); or At least one bathroom in the dwelling...
-
§8.21(c)(2)(i) General
A recipient may comply with the requirements of this section in its programs and activities receiving Federal financial assistance through such means as location of programs or services...
-
QUESTION: WHERE THE TRACK ADJACENT TO A PLATFORM IS NOT SHARED WITH FREIGHT, ARE THERE ANY CIRCUMSTANCES IN WHICH AN APPROACH OTHER THAN LEVEL BOARDING IS ALLOWABLE?
If FRA or FTA agrees that level boarding is not physically feasible, then the railroad would meet the performance standard of section 37.42(a) at the station through the means and process...
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
§35.150(b)(1)
A public entity may comply with the requirements of this section through such means as redesign of equipment, reassignment of services to accessible buildings, assignment of aides to beneficiaries...
-
11B-404.3.2 Maneuvering clearance
Clearances at power-assisted doors and gates shall comply with Section 11B-404.2.4....
-
11B-209.4 Valet parking
Parking facilities that provide valet parking services shall provide at least one passenger drop-off and loading zone complying with Section 11B-503....