Voting Area: The pedestrian route within the voting area contains a thermostat that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor...
Search Results "Ground Floor Exit"
Commonly Searched Documents
-
Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)
- Access-Able Designs Shower Transfer Bench SH-400-2SDL
-
Safe Harbor
Examples A public university library built in 1998 has light switches at 53 inches above the floor....
-
[2010 ADAS] 105.2.1 ANSI/BHMA
BHMA Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 17th Floor New York, NY 10017-6603 Standard Reference Number Title Referenced...
-
General [4.1.6(1)]
For example, if a toilet room renovation is limited to replacement of a lavatory and reflooring, then the new lavatory and floor must comply; where the work is more extensive and also involves...
-
Accessible Room Set-Up
An accessible floor plan is one in which people who use mobility devices (e.g., wheelchairs, scooters, walkers, crutches, canes) can maneuver throughout and use the amenities independently...
-
F217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
d. ii.
hand and does not require tight grasping and twisting actions of the wrist to operate at the following locations: (1) Main Lobby men's and women's toilet stall doors; (2) Second Floor...
-
Can back doors and freight elevators be used to satisfy the program accessibility requirement?
For example, a back door is acceptable if it is kept unlocked during the same hours the front door remains unlocked; the passageway to and from the floor is accessible, well-lit, and neat...
-
308.2.2 Obstructed High Reach
Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction....
-
F. Check-In Areas
This may be a part of the reception counter that is no higher than 36 inches above the floor, a folding shelf or an adjacent table, or a clip board....
-
217.4 TTYs
Separate requirements are provided based on the number of public pay telephones provided at a bank of telephones, within a floor, a building, or on a site....
-
4.10.14* Emergency Communications
The highest operable part of a two-way communication system shall be a maximum of 48 in (1220 mm) from the floor of the car....
-
Kitchen Electrical/Lighting/Mechanical
Low voltage lighting saves energy Low voltage lights also improves visual acuity in cabinets Hot water floor heating to keep heat low in the room for children, shorter people...
-
Accessible Route [9.2.2(2)]
Recommendation: ADAAG does not address furniture, but it is recommended that where dressers are provided, clear floor space should be provided so that people using wheelchairs can access...
-
Scoping [4.1.3(4)]
Compliance is required where stairs are the only connection between two levels, such as between floors in buildings without elevators....
-
Room Dimensions
For single-user toilet rooms, key considerations include the configuration of water closets and lavatories, clear floor spaces required at fixtures, turning space, the location and swing...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Power Chair
chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Scooter
scooter users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
Locating Controls & Devices: Percent of People Who Can Reach the Matrix Cell Indicated While Holding 5 lb Weight - Side Approach Manual Wheelchair
chair users represented as the percentage of users able to retrieve and place a 5 lb object on a target shelf in the lateral or sideways reach direction for a given (a) height from the floor...
-
9.5 LOCKER ROOMS
., intended for use by people in wheelchairs shall be located no higher than 48 in (1220 mm) above the finished floor....