When the running slope of a walking surface exceeds 5%, it must comply with the accessibility requirements for ramps....
Search Results "Safety Requirement"
-
11B-403.3 Slope
-
11B-221.3 Companion seats
At least one companion seat complying with Section 11B-802.3 shall be provided immediately adjacent to each wheelchair space required by Section 11B-221.2.1....
-
Clear floor space beside or between beds must be 36" wide
Remember that because the clear floor space required by 806.2.3 will be deeper than 24" to end up beside or between the beds where it will be usable, it will be in an alcove that is at least...
- Corada Product Certification Process
-
Accessible Product Certification Process
Surveillance helps to ensure that the certified product continues to meet the accessibility requirements of the indicated certification level....
-
Location: ADA Standard Section 206.4.4.1
Section 206.4.4.1 covers scoping requirements in the most current ADA Standards for the location of entrances in transportation facilities.
-
Equivalent Facilitation: ADA Standard Section 103
Section 103 of the ADA Standards covers information on equivalent facilitation in the 2010 ADA Standards.
-
Sleeping Areas: ADA Standard Section 806.2.3
EXCEPTION: Where a single clear floor space complying with 305 positioned for parallel approach is provided between two beds, a clear floor or ground space shall not be required on both...
-
Luxury Boxes, Club Boxes, and Suites in Arenas, Stadiums, and Grandstands: ADA Standard Section 221.2.1.2
Section 221.2.1.2 covers scoping requirements in the ADA for wheelchair spaces at luxury boxes, club boxes, and suites in arenas, stadiums and grandstands.
-
11B-504.2 Treads and risers
Exception: Curved stairways with winder treads are permitted at stairs which are not part of a required means of egress....
-
11B-223.1.1.1 Area alterations
medical facility shall comply with Section 11B-805.2 until the number of patient bedrooms or resident sleeping rooms provided within the area of renovation complies with the minimum number required...
-
11B-404.3.6 Break out opening
Exception: Where manual swinging doors and gates comply with Section 11B-404.2 and serve the same means of egress compliance with Section 11B-404.3.6 shall not be required....
-
11B-904.2 Approach
All portions of counters required to comply with Section 11B-904 shall be located adjacent to a walking surface complying with Section 11B-403. Advisory 11B-904.2 Approach....
-
11B-504.2 Treads and risers
Exception: Curved stairways with winder treads are permitted at stairs which are not part of a required means of egress....
-
11B-223.1.1.1 Area alterations
medical facility shall comply with Section 11B-805.2 until the number of patient bedrooms or resident sleeping rooms provided within the area of renovation complies with the minimum number required...
-
11B-404.3.6 Break out opening
Exception: Where manual swinging doors and gates comply with Section 11B-404.2 and serve the same means of egress compliance with Section 11B-404.3.6 shall not be required....
-
11B-904.2 Approach
All portions of counters required to comply with Section 11B-904 shall be located adjacent to a walking surface complying with Section 11B-403. Advisory 11B-904.2 Approach....
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
11B-1002.6.3 Wheelchair storage space
Wheelchair storage spaces complying with Section 11B-305 shall be provided in or adjacent to unload areas for each required transfer device and shall not overlap any required means of egress...
-
§ 1194.3(c)
(c) Except as required to comply with the provisions in this part, this part does not require the installation of specific accessibility-related software or the attachment of an assistive...
-
5.8.2.7.1 Mammography Chair Footrest
Mammography chairs must meet the requirements for equipment used for patient in a seated position with the additional requirement that any footrests must accommodate and ride over the base...
-
409.3 Elevator Doors
EXCEPTION: Doors shall not be required to comply with the maneuvering clearance requirements in 404.2.4.1 for approaches to the push side of swinging doors....
-
R217 Handrails (Section-by-Section Analysis)
R217 HandrailsĀ (Section-by-Section Analysis) Handrails are not required on pedestrian circulation paths....
-
f. Duplicative or Overlapping Federal Rules
Duplicative or Overlapping Federal Rules The Department is not aware of any existing federal regulations that impose duplicative, overlapping, or conflicting requirements relative to...