altering a load-bearing member that is an essential part of the structural frame; or because other existing physical or site constraints prohibit modification or addition of elements, spaces...
Search Results "Occupiable Space"
Commonly Searched Documents
- 
    
  
  Technically Infeasible
  
 - 
    
  
  Definition [F106.5]
  
Pedestrian routes that are developed primarily to connect accessible elements, spaces, and buildings within a site are not a trail....
 - 
    
  
  e-ii
  
Does the floor area of the elevator car have space to enter, reach the controls, and exit?...
 - 
    
  
  902.4 Dining Surfaces and Work Surfaces for Children's Use
  
EXCEPTION: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with 902.4 where a clear floor or ground space complying...
 - 
    
  
  4.14.1 Minimum Number
  
They shall also be connected by an accessible route to all accessible spaces or elements within the building or facility....
 - 
    
  
  5b.
  
Does the floor area of the elevator car provide space for wheelchair users to enter, reach the controls, and exit the car?...
 - 
    
  
  4.2.6* Side Reach
  
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less than 9...
 - 
    
  
  Scoping [4.1.3(5)]
  
instead of ramps or elevators only in providing access to: performing areas in assembly occupancies wheelchair seating locations in assembly occupancies incidental space...
 - 
    
  
  4.14.1 MINIMUM NUMBER
  
They shall also be connected by an accessible route to all accessible spaces or elements within the building or facility....
 - 
    
  
  4.2.5 FORWARD REACH
  
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a))....
 - 
    
  
  A4.34.6.7 OVENS
  
Clear spaces at least 30 in (760 mm) wide under counters at the side of ovens are an added convenience....
 - 
    
  
  11B-1003.3 Clearances
  
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
 - 
    
  
  11B-902.4 Dining surfaces and work surfaces for children’s use
  
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground space...
 - 
    
  
  1009.10 Directional signage
  
At exits serving a required accessible space but not providing an approved accessible means of egress. 2. At elevator landings. 3. Within areas of refuge....
 - 
    
  
  11B-1003.3 Clearances
  
Although the minimum width of the clear pier space is 60 inches (1525 mm), it is recommended that piers be wider than 60 inches (1525 mm) to improve the safety for persons with disabilities...
 - 
    
  
  11B-902.4 Dining surfaces and work surfaces for children’s use
  
Exception: Dining surfaces and work surfaces that are used primarily by children 5 years and younger shall not be required to comply with Section 11B-902.4 where a clear floor or ground space...
 - 
    
  
  III-1.2000 Public accommodations
  
. , inns, hotels, motels) (except for owner-occupied establishments renting fewer than six rooms); 2) Establishments serving food or drink (e.g. , restaurants and bars); 3) Places...
 - 
    
  
  Dwelling Unit
  
"Dwelling" is defined in 24 CFR 100.20 as "any building, structure, or portion thereof which is occupied as, or designed or intended for occupancy as, a residence by one or more families...
 - 
    
  
  4.3.9 Doorway Design 
  
Adopting a clear opening width of 860 mm (34 in.) would accommodate the widest occupied devices in our sample....
 - 
    
  
  Facilities operated through contractual, licensing, or other arrangements with other public entities or private entities. (Section-by-Section Analysis)
  
If a prison is occupied by State prisoners and is inaccessible, the State is responsible under title II of the ADA. The same is true for a county or city jail....
 - 
    
  
  Technical Memorandum TM 2013-20 Valet Parking
  
The 1994 TAS (and 1991 ADAAG) required valet parking facilities to provide a passenger loading zone but exempted the facilities from providing accessible passenger and van parking spaces...
 - 
    
  
  Ground Surfaces
  
Section 1008.2.6 of the 2010 Standards provides technical requirements for accessible ground surfaces for play areas on accessible routes, clear floor or ground spaces, and turning spaces...
 - 
    
  
  Grab Bar Cross Sections
  
For consistency with specifications for handrails, the Board has revised requirements for size (609.2) and spacing (609.3)....
 - 
    
  
  F205.1 General
  
Operable parts on accessible elements, accessible routes, and in accessible rooms and spaces shall comply with 309. EXCEPTIONS: 1....