Builders Hardware Manufacturers’ Association 355 Lexington Avenue, 15th Floor New York, NY 10017 A 156.10-2022: Power Operated Pedestrian Doors 1010.3.2, 11B-404.2.9, 11B-404.3...
Search Results "Floor Surface"
-
BHMA
-
§ 36.401(d)(1)(i)
The facility housing the "professional office of a health care provider" only includes floor levels housing at least one health care provider, or any floor level designed or intended for...
-
§ 36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
106.5.47 Professional Office of a Health Care Provider
The facility housing the "professional office of a health care provider" only includes floor levels housing at least one health care provider, or any floor level designed or intended for...
-
711.4.1.2 Through-penetration firestop system
The system shall have an F rating and a T rating of not less than 1 hour but not less than the required rating of the floor penetrated....
-
407.4.8.2.1 Signal Type
The signal shall be an automatic verbal annunciator which announces the floor at which the car is about to stop....
-
Sec.36.401(d)(3)
For example, in a facility that houses a shopping center or shopping mall, or a professional office of a health care provider, the floors that are above or below an accessible ground floor...
-
Sec.36.401(d)(1)(i)
The facility housing the "professional office of a health care provider'' only includes floor levels housing at least one health care provider, or any floor level designed or intended for...
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
-
11B-407.2.2.2 Visible signals
Visible signal fixtures shall be centered at 72 inches (1829 mm) minimum above the finish floor or ground....
- SafePath Courtedge™ Reducer Ramps
-
M303.2.4.1.2 Height
Wheelchair spaces shall include toe clearance 9 inches (230 mm) high minimum above the floor measured to a depth of 6 inches (150 mm) maximum from the toe end of the wheelchair space....
-
4.1.2(16)
public telephones are provided, then accessible public telephones shall comply with 4.31, Telephones, and the following table: Number of public telephones provided on each floor...
-
705.1 General
Detectable warnings shall consist of a surface of truncated domes and shall comply with 705. Figure 705.1 Size and Spacing of Truncated Domes...
-
Boat Launch Ramp
A sloped surface designed for launching and retrieving trailered boats and other water craft to and from a body of water....
-
Confirm that the vibrotactile indications work
Confirm that the vibrotactile indications work The tactile arrow or vibrating surface should vibrate rapidly only during the walk interval for the street....
-
5.4.3.1 Positioning Support Height for Imaging Equipment
Positioning supports should be positioned 3 to 6 inches above the transfer surface....
-
R305.2.6 Boarding Platforms
At boarding platforms for buses and rail vehicles, detectable warning surfaces shall be placed at the boarding edge of the platform....
-
e-i
Is the curb ramp surface at least 36 inches wide, excluding flared sides? [ADA Standards § 4.7.3] Yes No...
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....
-
RAMP
A walking surface that has a running slope steeper than one unit vertical in 20 units horizontal (5-percent slope)....
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2. ...
-
11B-502.6.4 Marking
Each accessible car and van space shall have surface identification complying with either Section 11B-502.6.4.1 or 11B-502.6.4.2....