Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
Search Results "Sign Clear Floor Space"
-
308.3.1 Unobstructed
-
11B-308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1219 mm) maximum and the low side...
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
ACCESSIBLE ROUTE
A continuous unobstructed path connecting all accessible elements and spaces in a building or facility....
-
307.3 Post-Mounted Objects
objects mounted on posts or pylons shall overhang circulation paths 12 inches (305 mm) maximum when located 27 inches (685 mm) minimum and 80 inches (2030 mm) maximum above the finish floor...
- Access Board: Accessible Passenger Loading Zones
-
F208.2.4 Van Parking Spaces
For every six or fraction of six parking spaces required by F208.2 to comply with 502, at least one shall be a van parking space complying with 502....
-
208.2.4 Van Parking Spaces
For every six or fraction of six parking spaces required by 208.2 to comply with 502, at least one shall be a van parking space complying with 502....
-
11B-216.2 Designations
Interior and exterior signs identifying permanent rooms and spaces shall comply with Sections 11B-703.1, 11B-703.2, 11B-703.3, and 11B-703.5....
-
7b.
[ADA Stds 4.13.9] Yes _____ No _____ A clear floor space on the latch side of the door (pull side) allows a person using a wheelchair or scooter to pull the door open and then...
-
Location of Accessible Parking Spaces
Section 208.3 specifies the location of accessible parking spaces....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
409.3.2 Location
Elevator car doors or gates shall be positioned at the narrow end of the clear floor spaces required by 409.4.1....
-
703.5.6 Height from Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
703.5.6 Height From Finish Floor or Ground
Visual characters shall be 40 inches (1015 mm) minimum above the finish floor or ground....
-
11B-904.4.2 Forward approach
Knee and toe space complying with Section 11B-306 shall be provided under the counter....
-
F208.2.4 Van Parking Spaces
For every six or fraction of six parking spaces required by F208.2 to comply with 502, at least one shall be a van parking space complying with 502. [ECTCR UFAS 4.1.1(5)(c)]...
-
Use of the ISA Under the ABA
Like the ADA Standards, these standards mandate use of the ISA to label or provide direction to certain accessible spaces and elements (§F216 and §703.7.2.1)....
-
308.3.1 Unobstructed
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side...
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
11B-206.5.2 Rooms and spaces
Within a building or facility, every door, doorway or gate serving rooms and spaces complying with this chapter shall comply with Section 11B-404....
-
Accessible Route
A continuous unobstructed path connecting all accessible elements and spaces of a building or facility....