Additionally, the final rule also exempts weight scales which contain a wheelchair space complying with M303 and that have a seat integral to the equipment from complying with M302 (M302.1...
Search Results "Wheelchair Scale"
-
M101.2 Application (Section-by-Section Analysis)
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
11B-1002.4.4.3 Permitted protrusions in wheelchair spaces
Objects are permitted to protrude a distance of 6 inches (152 mm) maximum along the front of the wheelchair space, where located 9 inches (229 mm) minimum and 27 inches (686 mm) maximum...
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
11B-1009.3 Sloped entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
1009.3 Sloped Entries
Personal wheelchairs and mobility devices may not be appropriate for submerging in water....
-
M304.2 Standing Surface
Equipment surfaces on which patients stand must comply with M304.2
-
M305.3.2 Height
The height of gripping surfaces for standing supports shall be based on the position of the standing supports in relation to the standing surfaces they serve. Horizontal standing...
-
M304.2.1 Slip Resistant
The surface on which the patient stands shall be slip resistant.
-
M304 Diagnostic Equipment Used by Patients in Standing Position
[See subsections ...]
-
M304.2.1 Slip Resistant (Section-by-Section Analysis)
The MDE NPRM proposed to require that the standing surface on which patients stand be slip resistant. One manufacturer commented on this requirement, requesting that the rule provide...
-
M305.3.2 Height (Section-by-Section Analysis)
For horizontal supports, the MDE NPRM proposed a gripping surface height of 34 inches minimum and 38 inches maximum above the standing surface. There were no public comments on this...
-
M304.2 Standing Surface (Section-by-Section Analysis)
The MDE NPRM proposed to require that the standing surface on which patients stand be slip resistant. In preparing the final rule, the Board has determined that as previously drafted...
-
M304.2 Standing Surface
The surface on which the patient stands shall be slip resistant.
-
M304.1 General
Diagnostic equipment used by patients in a standing position shall comply with M304.
-
M304 Diagnostic Equipment Used by Patients in Standing Position
[See subsections ...]
-
T602.4 Size
Wheelchair spaces shall be 30 inches (760 mm) minimum in width and 48 inches (1220 mm) minimum in length....
-
11B-206.7.2 Wheelchair spaces
Platform lifts shall be permitted to provide an accessible route to comply with the wheelchair space dispersion and line-of-sight requirements of Sections 11B-221 and 11B-802....
-
Categorization of wheelchair versus other power-driven mobility devices. (Section-by-Section Analysis)
Categorization of wheelchair versus other power-driven mobility devices....
-
Integration
Under section 221.2.2, wheelchair spaces must be integrated throughout seating areas....
-
2. In § 37.3, add the definition “Direct threat” and revise the definition “Wheelchair” to read as follows
In § 37.3, add the definition “Direct threat” and revise the definition “Wheelchair” to read as follows:...