Search Results "Unobstructed Transfer"
- Figure 1008.3.2 Transfer Steps – Drawing from the U.S. Access Board
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space.
-
1014.2.1.2 Floor Height
The camp shelter floor at the entrance shall be 19 inches (485 mm) high maximum measured from the clear ground space.
-
3. Are ramps, transfer systems, and stairs permitted to be counted as play components?
Are ramps, transfer systems, and stairs permitted to be counted as play components? No....
-
1b
Do they have a fixed or folding seat between 17"-19" above the floor, onto which a person who uses a wheelchair may transfer to shower?...
-
5.2.3 Transfer Surface Measurement
5.2.3 Transfer Surface Measurement. The transfer surface should be measured from the center-point of each side of the transfer surface....
-
1i
Are all of the small showers free of curbs or lips greater than 1/2" high at the shower floor that would impede wheelchair approach and transfer onto the folding shower seat?...
-
Ground Level and Elevated Play Components: ADA Standard Section 1008.2.1
Transfer systems complying with 1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided no more than 25 percent of the...
-
11B-1008.2.1 Ground level and elevated play components
Exceptions: Transfer systems complying with Section 11B-1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided...
-
11B-1008.2.1 Ground level and elevated play components
Exceptions: Transfer systems complying with Section 11B-1008.3 shall be permitted to connect elevated play components except where 20 or more elevated play components are provided...
-
M302.2.2 Sunset Provision (Section-by-Section Analysis)
(Significant Changes – Transfer Surface Adjustability), this is a new provision added to the final rule in conjunction with the new requirement of a low height range in M302.2.1....
-
4.2.5* Forward Reach
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a)). The minimum low forward reach is...
-
4.2.6* Side Reach
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less...
-
4.2.5 FORWARD REACH
If the clear floor space only allows forward approach to an object, the maximum high forward reach allowed shall be 48 in (1220 mm) (see Fig. 5(a)). The minimum low forward reach is...
-
4.2.6* SIDE REACH
If the clear floor space allows parallel approach by a person in a wheelchair, the maximum high side reach allowed shall be 54 in (1370 mm) and the low side reach shall be no less...
-
Reach Ranges and Operability Requirements
Section 308 of ABAAS identifies the following reach requirements: Unobstructed Reaches—When a forward or side reach is unobstructed, the object to be reached must be no higher than...
-
5.2.2.1 Transfer Surface Width Recommendations for M302
5.2.2.1 Transfer Surface Width Recommendations for M302 The Committee recommends 21 inches for the minimum width of the transfer surface of examination chairs and other equipment primarily...
-
608.5.1 Transfer Type Shower Compartments
608.5.1 Transfer Type Shower Compartments....
-
4.21.3 Seat
Seats are only required in transfer showers, which were not used in any of the designs reviewed....
-
5.1.1 Transfer Surface Height Adjustability
5.1.1 Transfer Surface Height Adjustability. The transfer surface should have an adjustable height in small virtually continuous increments....
-
5.1.2 Transfer Surface High Height
5.1.2 Transfer Surface High Height. The transfer surface should have an adjustable height range with an upper height measuring at least 25 inches....
-
8. Can an elevated crawl tube be used to connect to a play component required to be accessible? Can that crawl tube also be considered an accessible play component?
Yes, where transfer access is provided on a composite play structure elevated play components such as a crawl tube are permitted to connect to other play components....
-
M301.3.1 Transfer Supports
Transfer surfaces required by M301.2 shall provide transfer supports and shall comply with M305.2....
-
Transfer Surface Size – M302.2.2 Seated Position
Transfer Surface Size – M302.2.2 Seated Position The issue of seat depth was discussed and decided during the full committee meetings as follows: depth of 17 inches minimum....