Error/Omission: Where permanent room identification signage is provided, it is mounted in the wrong location. Result: People who are blind or visually impaired are trained...
Search Results "Stair Tread"
Commonly Searched Documents
-
Signage
-
11B-703 Signs
11B-703 Signs.
-
11B-703.4.1 Height above finish floor or ground
11B-703.4.1 Height above finish floor or ground. Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the...
-
11B-703.4.1 Height above finish floor or ground
Tactile characters on signs shall be located 48 inches (1219 mm) minimum above the finish floor or ground surface, measured from the baseline of the lowest Braille cells and 60...
-
11B-216 Signs
[See subsections ...]
-
11B-703 Signs
[See subsections ...]
-
Line Spacing: ADA Standard Section 703.5.9
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
11B-703.5.9 Line spacing
Spacing between the baselines of separate lines of characters within a message shall be 135 percent minimum and 170 percent maximum of the character height.
-
STAIR
STAIR. A change in elevation, consisting of one or more risers....
-
Stairs and Escalators in Existing Buildings: ADA Standard Section 206.2.3.1
Section 206.2.3.1 covers the scoping requirements for accessible routes between stairs and escalators in existing buildings.
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
-
Circular Cross Section and Clearance (§505.5, §505.7)
Circular Cross Section and Clearance (§505.5, §505.7)
-
11B-703.1.1.2 Inspection
11B-703.1.1.2 Inspection. Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final...
-
11B-703.1.1.2 Inspection
Signs and identification devices shall be field inspected after installation and approved by the enforcing agency prior to the issuance of a final certificate of occupancy per...
- How Blind People Find Braille Signs
- 703.4.1 Raised Letter and Braille Signage Height
-
Re: 703 Signs
Requires the Accessibility Specialist plan or above. (Login or upgrade your account!)
-
Re: 216 Signs
216.6 Entrances. Where not all entrances comply with 404, entrances complying with 404 shall be identified by the International Symbol of Accessibility complying with 703.7.2.1....
-
STAIR
A change in elevation, consisting of one or more risers.
- Figure 703.4.2 Location of Tactile Signs at Doors – Drawing from the U.S. Access Board
-
Visual Characters: ADA Standard Section 703.5
Visual characters shall comply with 703.5. EXCEPTION: Where visual characters comply with 703.2 and are accompanied by braille complying with 703.3, they shall not be required to...
-
11B-703.5 Visual characters
Visual characters shall comply with Section 11B-703.5. Exception: Where visual characters comply with Section 11B-703.2 and are accompanied by Braille complying with Section...
-
11B-703.5.7 Stroke thickness
Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADAS] 703.5.7 Stroke Thickness. Stroke...
-
703.4 Installation Height and Location
Signs with tactile characters shall comply with 703.4.