Where common use areas are provided for the use of residents, it is presumed that all such common use areas "serve" accessible dwelling units unless use is restricted to residents occupying...
Search Results "Single-Story Dwelling Unit (FHA)"
Commonly Searched Documents
-
206.2.3 Multi-Story Buildings and Facilities
-
809.1 General
Residential dwelling units required to provide mobility features shall comply with 809.2 through 809.4....
-
Guidelines for Requirement 5
The Guidelines for Requirement 5 present design specifications for providing dwelling units that contain light switches, electrical outlets, thermostats, and other environmental controls...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
11B-208.3.2 Residential facilities
Spaces provided in accordance with Section 11B-208.2.3.2 shall be dispersed throughout all types of parking provided for the residential dwelling units....
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
11B-208.2.3.1 Parking for residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with Section 11B-502 shall be provided for each residential dwelling...
-
1132A.8 Hand-activated door hardware
Latching and locking doors that are hand-activated and on an accessible route shall be operable with a single effort by lever-type hardware, panic bars, push-pull activating bars or other...
-
General: ADA Standard Section 229.1
Section 229.1 of the ADA Standards covers information in the current ADA Standards on scoping requirements for windows.
-
708.4.2 Residential Dwelling Unit Interface
708.4.2 Residential Dwelling Unit Interface....
-
11B-213.2.1 Unisex (single-user or family) toilet and unisex (single-user or family) bathing rooms
Unisex (single-user or family) toilet rooms shall contain not more than one lavatory, and not more than two water closets without urinals or one water closet and one urinal....
-
809.5.4 Prohibited Use
Visible alarm appliances used to indicate residential dwelling unit smoke detection or building fire alarm activation shall not be used for any other purpose within the residential dwelling...
-
Turning Space: ADA Standard Section 809.2.2
All rooms served by an accessible route shall provide a turning space complying with 304. EXCEPTION: Turning space shall not be required in exterior spaces 30 inches (760 mm)...
-
11B-809.7.1 Width
The clear width for the accessible route shall be 36 inches (914 mm) minimum. Exception: The clear width shall be permitted to be reduced to 32 inches (813 mm) minimum at doors.
-
11B-809.10.6 Showers
Showers required by Section 11B-809.10 shall comply with this section.
-
11B-809.7.2 Changes in level
Changes in level shall comply with Sections 11B-303.2 and 11B-303.3. Ramps complying with Section 11B-405, elevators complying with Section 11B-407 or platform lifts complying with...
-
11B-809.9.6 Controls
Controls for faucets shall comply with Section 11B-309.1. Hand-operated metering faucets shall remain open for 10 seconds minimum.
-
11B-809.2.2 Turning space
All rooms served by an accessible route shall provide a turning space complying with Section 11B-304. Exception: Turning space shall not be required in exterior spaces 30 inches...
-
11B-809.12 Electrical receptacles, controls and switches
Electrical receptacles on branch circuits of 30 amperes or less, communication system receptacles, controls and switches shall be located as follows: Where there is no...
-
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C
Comparison of Single-User Toilet Room Layouts: 1A, 1B, and 1C 1991 Standards Plan-1A: 1991 Standards Minimum with Out-Swinging Door 5’-0" x 7’-3"...
-
F208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
208.2.3.1 Parking for Residents
Where at least one parking space is provided for each residential dwelling unit, at least one parking space complying with 502 shall be provided for each residential dwelling unit required...
-
1133A.4 Countertops
Sinks and work surfaces may be a single integral unit a minimum of 60 inches (1524 mm) in length, or be separate components....