be of less than 1-hour fire-resistance-rated construction for a width of 4 feet (1220 mm) measured from the interior side of the wall for Groups R and U and 10 feet (3048 mm) for other occupancies...
Search Results "Occupancy"
Commonly Searched Documents
-
704.11 Parapets
-
T603 Wheelchair Securement Systems
their accompanying securement systems, the Access Board essentially restated requirements in the existing guidelines: wheelchair securement systems must secure a wheelchair so that the occupant...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_....
-
14. Inconsistent State laws
104.10(a) states that compliance with the regulation is not excused by State or local laws limiting the eligibility of qualified handicapped persons to receive services or to practice an occupation...
-
Adaptability
Adaptability Toilet rooms designed for use by a single occupant of a specific space, can be designed to be "adaptable" so that accessible elements can be installed when needed after construction...
-
Do requirements for “public entrances” apply only to those entrances used by the public?
This is intended to apply specifically to entrances where user identity is verified and entry is strictly limited to certain occupants, but no one else, including guests or companions of...
-
68.1. Authority
amended effective March 1, 2007, 32 TexReg 884) These rules are promulgated under the authority of Texas Government Code, Chapter 469, Elimination of Architectural Barriers, and Texas Occupations...
-
11B-229.1 General
Where glazed openings are provided in accessible rooms or spaces for operation by occupants, at least one opening shall comply with Section 11B-309 _|Operable Parts|_....
-
1010.1.5 Floor elevation
Doors serving equipment spaces not required to be accessible in accordance with Section 11B-203.5 and serving an occupant load of five or less shall be permitted to have a landing on one...
-
[F] 907.5.2.3.3 Group R-2
In Group R-2 occupancies required by Section 907 to have a fire alarm system, each story that contains dwelling units and sleeping units shall be provided with the capability to support...
-
11B-608.3 Grab bars
Grab bars shall not be required to be installed in a shower located in a bathing facility for a single occupant accessed only through a private office, and not for common use or public use...
-
Re: Lavatories Adjacent to Partitions
Clear Floor Space is defined as the minimum unobstructed floor or ground space required to accommodate a single, stationary wheelchair and occupant. ...
-
1010.1.5 Floor elevation
In Group R-3 occupancies not required to be adaptable or accessible, the landing at an exterior doorway shall be not more than 7¾ inches (197 mm) below the top of the threshold, provided...
-
604.4 Seats
A water closet in a toilet room for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 604.4. 2....
-
229 Windows
Scoping provisions for windows require that at least one glazed opening, where provided for operation by occupants, meet technical criteria for operable parts....
-
607.4 Grab Bars
Grab bars shall not be required to be installed in a bathtub located in a bathing facility for a single occupant accessed only through a private office and not for common use or public use...
-
1007.6 Areas of refuge
The maximum travel distance from any accessible space to an area of refuge shall not exceed the travel distance permitted for the occupancy in accordance with Section 1015.1....
-
607.4 Grab Bars
Grab bars shall not be required to be installed in a bathtub located in a bathing facility for a single occupant accessed only through a private office and not for common use or public use...
-
604.4 Seats
A water closet in a toilet room for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 604.4. 2....
-
606.3 Height
A lavatory in a toilet or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 606.3....
-
Place of lodging
of this part, a facility is a place of lodging if it - (1) Provides guestrooms for sleeping for stays that are primarily short-term in nature (generally two weeks or less) where the occupant...
-
604.4 Seats
A water closet in a toilet room for a single occupant accessed only through a private office and not for common use or public use shall not be required to comply with 604.4. 2....
-
Accessible Route [9.2.2(2)]
Accessible Route [9.2.2(2)] An accessible route at least 36 inches wide must be provided to all accessible elements, including phones and thermostats, provided for use by room occupants...
-
§100.20 Person in the business of selling or renting dwellings
sales or rental services in two or more transactions involving the sale or rental of any dwelling or any interest therein; or (c) Is the owner of any dwelling designed or intended for occupancy...