Clear Floor Space [4.27.2] Clear floor space for a forward or side approach is required at controls, dispensers, receptacles, and other operable equipment as specified in 4.2; those recessed...
Search Results "Monitoring Space"
Commonly Searched Documents
- 
    
  
  Clear Floor Space [4.27.2]
  
- 
    
  
  4.2.3* Wheelchair Turning Space
  The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b)).... 
- 
    
  
  4.2.3* WHEELCHAIR TURNING SPACE
  The space required for a wheelchair to make a 180-degree turn is a clear space of 60 in (1525 mm) diameter (see Fig. 3(a)) or a T-shaped space (see Fig. 3(b)).... 
- 
    
  
  1009.7.1 Size
  Each exterior area for assisted rescue shall be sized to accommodate wheelchair spaces in accordance with Section 1009.6.3.... 
- 
    
  
  A4.2.3 Wheelchair Turning Space
  These guidelines specify a minimum space of 60 in (1525 mm) diameter or a 60 in by 60 in (1525 mm by 1525 mm) T-shaped space for a pivoting 180-degree turn of a wheelchair.... 
- 
    
  
  M. Turning Space
  M. Is there an area in each public restroom in which a person who uses a wheelchair can turn around - either a 60" diameter circle or a "T"-shaped turn area as shown in Figure 3... 
- 
    
  
  Clear Floor Space [4.18.3]
  Clear Floor Space [4.18.3] Clear floor space at least 30 inches wide is required, including between partitions where they are provided (when shields do not extend beyond the front of... 
- 
    
  
  11B-809.10.4 Sufficient maneuvering space
  The clear maneuvering space shall be permitted to include knee and toe clearance under bathroom fixtures.... 
- 
    
  
  4.35.2 Clear Floor Space
  A clear floor space allowing a person using a wheelchair to make a 180-degree turn shall be provided in every accessible dressing room entered through a swinging or sliding door.... 
- 
    
  
  4.3.4 Passing Space
  If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed... 
- 
    
  
  4.3.4 PASSING SPACE
  If an accessible route has less than 60 in (1525 mm) clear width, then passing spaces at least 60 in by 60 in (1525 mm by 1525 mm) shall be located at reasonable intervals not to exceed... 
- 
    
  
  A4.2.3 WHEELCHAIR TURNING SPACE
  This standard specifies a minimum space of 60 in (1525 mm) diameter for a pivoting 180-degree turn of a wheelchair.... 
- 
    
  
  605.3 Clear Floor Space
  605.3 Clear Floor Space. A clear floor or ground space complying with 305 positioned for forward approach shall be provided.... 
- 
    
  
  Inside Dimensions of Elevator Cars: ADA Standard Section 409.4.1
  Section 409.4.1 covers the current ADA Standards for the inside dimensions of private residence elevator cars. 
- 
    
  
  11B-703.5.8 Character spacing
  Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces.... 
- 
    
  
  11B-804.6.1 Clear floor or ground space
  A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap.... 
- 
    
  
  11B-804.6.1 Clear floor or ground space
  A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap.... 
- 
    
  
  11B-804.6.1 Clear floor or ground space
  A clear floor or ground space complying with Section 11B-305 shall be provided at each kitchen appliance. Clear floor or ground spaces shall be permitted to overlap.... 
- 
    
  
  11B-206.7.3 Incidental spaces
  Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum.... 
- 
    
  
  11B-206.7.3 Incidental spaces
  Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum. ... 
- 
    
  
  11B-206.7.3 Incidental spaces
  Platform lifts shall be permitted to provide an accessible route to incidental spaces which are not public use spaces and which are occupied by five persons maximum.... 
- 
    
  
  1011.2 Clear Ground Space
  A clear ground space complying with 1011.2 shall be provided at outdoor constructed features. EXCEPTIONS: 1. ... 
- 
    
  
  11B-409.4.1 Inside dimensions of elevator cars
  Elevator cars shall provide a clear floor space of 36 inches (914 mm) minimum by 48 inches (1219 mm) minimum and shall comply with Section 11B-305.... 
- 
    
  
  1008.3.1.3 Transfer Space
  1008.3.1.3 Transfer Space. A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform.... 