The amount of clear floor space in front of a bathtub required by ADAAG (30"-48" min depth depending on the direction of travel by the length of the tub including a seat at the head of the...
Search Results "Head End Wall"
-
4.20.2 Floor Space
-
M301.2.3 Transfer Surface Transfer Sides
The option to transfer will be required only on one long side of the patient scanning/imaging table and not at the “foot” or “head” end of such surfaces....
-
1134A.5, Item 2
Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars....
-
1134A.5, Item 2
Reinforced walls for grab bars. A bathtub installed without surrounding walls shall provide reinforced areas for the installation of floor-mounted grab bars....
- Zurn Z5310 Wall Hung Lavatory
- Zurn Z5350 Wall Hung Lavatory
-
4.20.3 Seat
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
-
4.20.3 SEAT
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
- Haws Barrier-Free Chilled Wall Mount Fountain H1001.8HPS
- Haws Barrier-Free Chilled Wall Mount Fountain H1001.8
- American Dryer, Inc Wall Guard Accessory
-
4.34.5.4(2) Seat
An in-tub seat or a seat at the head end of the tub shall be provided as shown in Fig. 33 and 34. The structural strength of seats and their attachments shall comply with 4.26.3....
-
11B-806.2.3.1 Personal lift device floor space
shall be parallel to the long side of the bed and extend under the bed to points horizontally 30 inches (762 mm), vertically 7 inches (178 mm) and not more than 12 inches (305 mm) from the head...
- Nana Wall Systems, Inc. Folding Glass Walls Solid Wood WD65
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8HO
- Maddak Wall Switch Extension Handle
-
4.9.4(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall or post....
-
4.8.5(6)
(6) Ends of handrails shall be either rounded or returned smoothly to floor, wall, or post....
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8
- Haws Barrier-Free Chilled Dual Wall Mount Fountain H1011.8HPS
-
H22
Is a second horizontal grab bar at least 36 inches long securely mounted on the back wall with one end no more than 6 inches from the side wall 33 to 36 inches above the floor?...
-
M19
Is a horizontal grab bar at least 40 inches long securely mounted on the adjacent side wall 33 to 36 inches above the floor with one end no more than 12 inches from the back wall?...
-
Clearances between a handrail and wall surface: 2012 NFPA 101 vs. 2010 ADA
ETA Interpretation/Opinion: Clearances between a handrail and wall surface: The 2010 ADA now requires the 1.5” as a minimum. 2012 NFPA 101 Life Safety Code will be requiring 2.25” minimum...