Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
Search Results "Floor Identification"
Commonly Searched Documents
-
11B-608.9 Shower floor or ground surface
-
11B-608.9 Shower floor or ground surface
Floor or ground surfaces of showers shall comply with Section 11B-302.1 and shall be sloped 1:48 maximum in any direction....
-
Clear Floor Space: Minimum Clear Floor Space Required for Forward and Side Approach - Scooter
This data depicts the amount of clear floor area required by persons using wheeled mobility devices when performing a forward or side reach to a target location (e.g., reaching to a...
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-408.4.2 Floor surfaces
Floor surfaces in elevator cars shall comply with Sections 11B-302 and 11B-303....
-
11B-809.10.6.3 Floor space
A clear maneuvering space 30 inches (762 mm) wide minimum by 48 inches (1219 mm) minimum in length shall be located outside the shower, with the width flush with the control wall and...
-
5.1.6 Clear Floor or Ground Space
A clear floor or ground space at least 36 inches (915 mm) by 48 inches (1220 mm) shall be provided parallel at the elevated entrance to the camp shelter....
-
Error/Omission: The door to the toilet room swings into the required clear floor space at accessible fixtures, controls, and dispensers.
For example, if a person using a wheelchair is positioned in the clear floor space at the paper towel dispenser and that clear floor space overlaps the space needed to swing the door open...
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
802.1.1 Floor or Ground Surface
The floor or ground surface of wheelchair spaces shall comply with 302. Changes in level are not permitted. EXCEPTION: Slopes not steeper than 1:48 shall be permitted....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
11B-811.2 Clear floor or ground space
A clear floor or ground space complying with Section 11B-305 shall be provided....
-
4.2.4.3 Surfaces for Wheelchair Spaces
Clear floor or ground spaces for wheelchairs shall comply with 4.5....
-
4.2.4.3 SURFACES FOR WHEELCHAIR SPACES
Clear floor or ground spaces for wheelchairs shall comply with 4.5....
-
Floor Requirement: ADA Standard Section 217.4.2
Section 217.4.2 covers scoping requirements in the current ADA Standards for TTYs on the floor of public and private buildings.
-
305 Clear Floor or Ground Space
[See subsections ...]
-
305 Clear Floor or Ground Space
[See subsections ...]
-
Common Questions (Clear Floor or Ground Space and Turning Space)
Common Questions
-
Can clear floor/ground space or turning space overlap other space requirements?
Yes, clear floor or ground spaces and turning space can overlap other required clearances, including other clear floor spaces, door maneuvering clearances, and fixture clearances....
-
Inpro Corporation JointMaster® 787 Series Floor Expansion Joint Covers
Requires the Premium User plan or above. (Login or upgrade your account!)
-
Signage [4.6.4]
Accessible spaces must be designated by the access symbol, which can be mounted on walls, posts, or from garage ceilings so that it is not obscured by vehicles parked in the space....
-
Is clear floor space required to be centered on elements?
The standards require the clear floor space to be centered on wheelchair accessible drinking fountains (forward approach), kitchen work surfaces, (forward approach), and washers and dryers...