907.2.1.2 Emergency power
Emergency voice/alarm communications systems shall be provided with an approved emergency power source.
-
4.28.3(7)
(7) In general, no place in any room or space required to have a visual signal appliance shall be more than 50 ft (15 m) from the signal (in the horizontal plane). In large rooms and...
-
4.28.3(8)
(8) No place in common corridors or hallways in which visual alarm signalling appliances are required shall be more than 50 ft (15 m) from the signal.
-
Visual Alarms [4.28.3]
Visual Alarms [4.28.3] In general, it is not sufficient to install visual signals only at audible alarm locations. Audible alarms installed in corridors and lobbies can be heard...
-
A4.28.3 Visual Alarms
The specifications in this section do not preclude the use of zoned or coded alarm systems.
-
4.28.3* Visual Alarms
Visual alarm signal appliances shall be integrated into the building or facility alarm system. If single station audible alarms are provided then single station visual alarm signals...
-
4.28.3(6)
(6) The appliance shall be placed 80 in (2030 mm) above the highest floor level within the space or 6 in (152 mm) below the ceiling, whichever is lower.
-
4.28.1 General
Alarm systems required to be accessible by 4.1 shall comply with 4.28. At a minimum, visual signal appliances shall be provided in buildings and facilities in each of the following...
-
4.28.1 GENERAL
Alarm systems required to be accessible by 4.1 shall comply with 4.28.
-
4.28.3* VISUAL ALARMS
If provided, electrically powered internally illuminated emergency exit signs shall flash as a visual emergency alarm in conjunction with audible emergency alarms. The flashing...
-
A4.28.3 VISUAL ALARMS
The specifications in this section do not preclude the use of zoned or coded alarm systems. In zoned systems, the emergency exit lights in an area will flash whenever an audible...
-
1. Job-Related
Job-Related If a qualification standard, test or other selection criterion operates to screen out an individual with a disability, or a class of such individuals on the basis of disability...
- Honeywell SpectrAlert Advance Selectable Output Devices
-
Rulemaking History
The ANSI A117.1 standard is a national consensus standard that provides technical requirements for accessible buildings and facilities....
-
§1630.15(b)(1) In general
It may be a defense to a charge of discrimination, as described in §1630.10, that an alleged application of qualification standards, tests, or selection criteria that screens out or tends...
-
1630.15(b)(1)
It may be a defense to a charge of discrimination, as described in section 1630.10, that an alleged application of qualification standards, tests, or selection criteria that screens out...
-
2012 Texas Accessibility Standards (TAS)
Elimination of Architectural Barriers Texas Government Code, Chapter 469 Administered by the Texas Department of Licensing and Regulation Effective March 15,...
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
809.5.1.1 Alarm Appliances
Where alarm appliances are provided within a residential dwelling unit as part of the building fire alarm system, they shall comply with 702....
-
Sec.36.406(b)
(b) The chart in the appendix to this section provides guidance to the user in reading appendix A to this part (ADAAG) together with subparts A through D of this part, when...