Stroke thickness of the uppercase letter “I” shall be 10 percent minimum and 20 percent maximum of the height of the character. [2010 ADA Standards] 703.5.7 Stroke Thickness....
Search Results "Exterior Exit Stairway"
Commonly Searched Documents
-
11B-703.5.7 Stroke thickness
-
1007.6.5 Identification
Where exit sign illumination is required by Section 1011.2, the area of refuge sign shall be illuminated....
-
907.2.2 Group B
A manual fire alarm system shall be installed in Group B occupancies having an occupant load of 500 or more persons or more than 100 persons above or below the lowest level of exit discharge...
-
1003.2.13.5.5 Identification
Where exit sign illumination is required by Section 1003.2.10.4, the area of refuge sign shall be illuminated....
-
Work Areas [4.1.1(3)]
Note that an accessible route through one work area ("research,") may be needed to provide access to an exit as part of an accessible means of egress....
-
1009.8 Two-way communication
Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator or bank of elevators on each accessible floor that is one or more stories above or below the level of exit...
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
A4.13.11 Door Opening Force
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert 3 lbf...
-
A4.13.11 DOOR OPENING FORCE
Although most people with disabilities can exert at least 5 lbf (22.2N), both pushing and pulling from a stationary position, a few people with severe disabilities cannot exert even...
-
1132A.3, Item 4
4. A nominal 32-inch (813 mm) clear opening provided by a standard 6-foot wide (1829 mm) sliding patio door assembly is acceptable.
-
2. a. ii. Accessible entrance and exit route
[See subsections ...]
-
4.9.4 HANDRAILS
Stairways shall have handrails at both sides of all stairs....
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADAS] 210.1 General. ...
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADAS] 210.1 General. Interior and exterior stairs that are part of a means of egress shall comply with 504....
-
11B-210.1 General
Interior and exterior stairs shall comply with Section 11B-504. [2010 ADA Standards] 210.1 General....
-
Character Proportions: ADA Standard Section 703.5.4
Characters shall be selected from fonts where the width of the uppercase letter “O” is 55 percent minimum and 110 percent maximum of the height of the uppercase letter “I”.
-
Character Spacing: ADA Standard Section 703.5.8
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.8 Character spacing
Character spacing shall be measured between the two closest points of adjacent characters, excluding word spaces. Spacing between individual characters shall be 10 percent minimum...
-
11B-703.5.4 Character proportions
Characters shall be selected from fonts where the width of the uppercase letter “O” is 60 percent minimum and 110 percent maximum of the height of the uppercase letter “I”. [2010...
-
203 General Exceptions
Areas that are used only as work areas shall be designed and constructed so that individuals with disabilities can approach, enter, and exit the areas....
-
Permanent Rooms and Spaces
Section 216.2 covers designations of permanent rooms and spaces, including pictograms provided as part of such signs. These types of signs are required to be tactile through the...
-
B. Braille Signs
B. Do the wall mounted signs provided for the rooms listed above have Braille and raised letters so that they can be read by persons who are blind or have low vision? [ADA Stds....
-
1009.4 Elevators
In order to be considered part of an accessible means of egress, an elevator shall comply with Sections 1009.4.1 and 1009.4.2.