The MDE NPRM proposed definitions for enforcing authority, medical diagnostic equipment, operable parts, and transfer surface....
Search Results "Equipment Console"
-
M102.1 Defined Terms (Section-by-Section Analysis)
-
3.3 Equipment Barriers and Solutions
Barriers Solutions Simple/Low cost Involved / High cost Display and/or controls on the equipment is not accessible Put tactile labels...
-
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position
5.6.1 Stirrups for Equipment Used by Patient in Supine, Prone, or Side-Lying Position....
-
Accessible Medical Equipment
We provide participants transfer assistance on and off of equipment (this includes use of lift equipment when needed). ...
-
5.8.1.1 Clear Platform Size Recommendation
5.8.1.1 Clear Platform Size Recommendation The Committee recommends a platform size with a minimum clear width of 32 inches and a minimum clear length of 40 inches. Rationale...
-
5.8.1.1 Clear Platform Size
5.8.1.1 Clear Platform Size. The platform should be a minimum clear width of 32-inches and a minimum clear length of 40-inches.
-
5.7.1 Lift Compatibility Clearance in Base for M301
maneuver far enough over the equipment to safely lower and raise the patient onto and off examination surfaces....
- NuStep T4r Recumbent Cross Trainer
- Selenia Dimensions Mammography System
- Selenia Performance Digital Mammography System
- Merlexi Craft™ Liberty MRI Wheelchairs
-
M305.4 Leg Supports (Section-by-Section Analysis)
The MDE Advisory Committee recommended adding additional language to this provision to clarify that “where the equipment provides stirrups, it must also provide an alternate method to support...
-
Figure M4: Overview of M303 Diagnostic Equipment for Use by a Patient While Seated in a Wheelchair and M304 Diagnostic Equipment for Use by a Patient in a Standing Position (Weight Scale Example)
Where the primary use of the equipment supports more than one patient position, it must comply with the requirements for each use. ...
-
Is network architecture covered by the FCC's Section 255 rules?
In addition to covering equipment and services, the FCC's rules require network architecture to be designed in a way that does not hinder access by people with disabilities....
-
M201.2 General Exception
Medical diagnostic equipment shall not be required to comply with one or more applicable requirements in the MDE Standards in the rare circumstances where compliance would alter diagnostically...
-
M301.4.2 Clearance Around Base
[See subsections ...]
-
M201.2 General Exception (Section-by-Section Analysis)
The MDE NPRM did not propose a general exception for diagnostic equipment that was not capable of meeting the MDE Standards. As described in Section IV.A.1....
-
D. Department of Justice Activities Related to Health Care Providers and Medical Equipment
the equipment for transfer; accessible medical equipment (e.g., examination tables and chairs, mammography equipment, weight scales); patient lifts and other methods for transferring individuals...
-
1. General Exception
, and would prevent the use of the equipment for its intended diagnostic purpose....
-
C. M303 Diagnostic Equipment Used by Patients Seated in a Wheelchair
M303 contains the technical requirements for diagnostic equipment used by patients seated in wheelchairs....
-
M301.4 Lift Compatibility (Section-by-Section Analysis)
This provision clearly states that diagnostic equipment shall comply with clearance in base or clearance around base....
-
Chapter 3: Technical Requirements
[See subsections ...]
-
Chapter 1: Application and Administration
[See subsections ...]
-
Wheelchair Space
Space for a single wheelchair and its occupant.